Technical information
COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-79
<INSTALL (at time of installation)>
F00-400-02
INIT-C/M/Y
Use it to read in the initial value of the toner density signal (SGNL, REF) of
the specified color.
• The value will be indicated on screen 3/4. Record it to the service label.
INIT-3
Reads the initial value of the toner density signal (SGNL, REF) of three
colors (C, M, Y) in sequence.
• The value will be indicated on screen 3/4. Record it to the service label.
INIT-7
Reads the initial value of the toner density signal (SGNL, REF) of the ATR
and SALT sensors in sequence.
• The value will be indicated on screens 3/4 and 4/4. Record it to the service
label.
<M> <S> <R> <P> <F>
FUNC
0
0
0
0
0
0
000
00
DISP
ADJUST
COUNTER
OPTION
TEST
INIT-M
SINIT-M
STIR-M
SPLY-M
INIT-3
SINIT-K
STIR-K
INIT-7
SINIT-4
STIR-4
SPLY-K
00
0
0
0
0
INIT-Y
SINIT-Y
STIR-Y
SPLY-Y
0
WINCLR-Y
WINCLR-M
0
0
0
0
INIT-C
SINIT-C
STIR-C
SPLY-C
0
WINCLR-C
0
WINCLR-4
WINCLR-K
INSTALL 1/4
<M> <S> <R> <P> <F>
0
0
000
FUNC
DISP
ADJUST
COUNTER
OPTION
TEST
RECV-Y
IMG-REG
REG-APER
0
LSNS-KIL 505g NLSET-KBODY
RECV-MRECV-C RECV-K
INSTALL 2/4
0
RECV-4