Technical information

COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-71
F00-300-30
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks Same as the reading under DISPLAY > ANALOG
BODY %
Indicates the machine internal humidity measured by the environment sensor.
Remarks Same as the reading under DISPLAY > ANALOG
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks Same as the reading under DISPLAY > ANALOG
<<<ZONE-A>>>
Indicates the zone in which the setting shown is effective.
FS-N1
Effective in plain paper mode and, in addition, when copying on a one-
sided copy or on the 1st side of a two-sided copy.
Settings range
–5 ~ +5 (Standard: 0)
Unit: 25 µA
FS-N2
Effective in plain paper mode and, in addition, when copying on the 2nd
side of a two-sided copy.
Settings range
–5 ~ +5 (Standard: 0)
Unit: 25 µA
FS-OHP
Effective in OHP mode.
Settings range
–5 ~ +5 (Standard: 0)
Unit: 25 µA
<M> <S> <R> <P> <F>
ADJUST
DISP
FUNC
COUNTER
OPTION
TEST
HV-FS 2/4
FS-T1
xxxx
FS-T2
xxxx
FS-S1-2
xxxx
FS-S2-1
xxxx
FS-UT1
xxxx
FS-UT2
xxxx
FS-OHP
xxxx
FS-#
xxxx
FS-N1
xxxx
<<<<<<< ZONE A >>>>>>>
FS-N2
xxxx
FS-S1-1
xxxx
FS-S2-2
xxxx
FS-S3-1
xxxx
FS-S3-2
xxxx