SERVICE MODE
S-70
REF.
If stray toner occurs for STMT size images before fixing, increase the set-
ting (so that the high-voltage output will increase) to limit the problem.
However, keep in mind that too high a setting will cause the paper to stick
to the guide before fixing, turning into a jam.
Note 1: The setting of this item will return to the default value when the PCB is re-
placed or the RAM is cleared, requiring input once again. Be sure to record
any new setting you have made on the service label.