Technical information
COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-66
F00-300-28
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
BODY %
Indicates the machine internal humidity measured by the environment sensor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
<<<ZONE-A>>>
Indicates the zone in which the setting shown is effective.
SP-N1
Effective in plain paper mode and, in addition, when copying on a one-
sided copy or on the 1st side of a two-sided copy.
Settings range
–5 ~ +5 (Standard: 0)
Unit: 25 µA
SP-N2
Effective in plain paper mode and, in addition, when copying on the 2nd
side of a two-sided copy.
Settings range
–5 ~ +5 (Standard: 0)
Unit: 25 µA
<M> <S> <R> <P> <F>
ADJUST
DISP
FUNC
COUNTER
OPTION
TEST
HV-SP 2/4
SP-T1
xxxx
SP-T2
xxxx
SP-S1-2
xxxx
SP-S2-1
xxxx
SP-UT1
xxxx
SP-UT2
xxxx
SP-OHP
xxxx
SP-#
xxxx
SP-N1
xxxx
<<<<<<< ZONE A >>>>>>>
SP-N2
xxxx
SP-S1-1
xxxx
SP-S2-2
xxxx
SP-S3-1
xxxx
SP-S3-2
xxxx
BODY
BODY
BODY
xxx
xxx
xxx
˚C
%
g