S-65
<HV-SP (separation high-voltage output fine-adjustment by
condition)>
F00-300-27
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks Same as the reading under DISPLAY > ANALOG
BODY %
Indicates the machine internal humidity measured by the environment sen-
sor.
Remarks Same as the reading under DISPLAY > ANALOG
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks Same as the reading under DISPLAY > ANALOG
SP-OFST
Adjusts the transfer high-voltage output.
Settings range
–5 ~ +5 (Standard: 0)
Unit: 25 µA
ZONE-A/B/C
Indicates the machine internal humidity absolute value (g) in the three
ranges of A through C.
Note 1: The setting of this item will return to the default value when the PCB is re-
placed or the RAM is cleared, requiring input once again. Be sure to record
any new setting you have made on the service label.