SERVICE MODE
S-62
F00-300-26
BODY °C
Indicates the machine internal temperature measured by the environment sensor.
Remarks Same as the reading under DISPLAY > ANALOG
BODY %
Indicates the machine internal humidity measured by the environment sensor.
Remarks Same as the reading under DISPLAY > ANALOG
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks Same as the reading under DISPLAY > ANALOG
<<<ZONE-A>>>
Indicates the zone in which the setting shown is effective.
TR-N1
Effective in plain paper mode and, in addition, when copying on a one-
sided copy or on the 1st side of a two-sided copy.
Settings range
–5 ~ +5 (Standard: 0)
Unit: 1.0 µA
TR-N2
Effective in plain paper mode and, in addition, when copying on the 2nd
side of a two-sided copy.
Settings range
–5 ~ +5 (Standard: 0)
Unit: 1.0 µA
TR-OHP
Effective in OHP mode.
Settings range
–5 ~ +5 (Standard: 0)
Unit: 1.0 µA