Technical information
COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-60
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
BODY %
Indicates the machine internal humidity measured by the environment sen-
sor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
>
Indicates the present environment.
ENV-A~G
Sets ON/OFF of the cassette heater.
Remarks The heater will turn on if the internal humidity absolute value exceeds
the setting.
OFF
Sets to OFF for all environment.
REF.
The settings of ‘ENV-SET’ are stored as soon as the CPU on the DC
controller PCB is supplied with power (i.e., when the power plug is
conected to the power outlet), and will be renewed every 8 hr.
<ENV-SET (setting operation conditions for the cassette)>
heater
F00-300-24
<M> <S> <R> <P> <F>
DISP
FUNC
COUNTER
OPTION
TEST
ADJUST
BODY
BODY
BODY
˚C27
28
624
%
g
to0g
to290g
to580g
to1050g
to1500g
to1800g
to2160g
OFF290g
OFF580g
OFF1050g
OFF1500g
ON1800g
ON
ON
2160g
ENV-A
ENV-B
ENV-C
>
ENV-D
ENV-E
ENV-F
ENV-G
OFF
ENV-SET READY READY USER