SERVICE MODE
S-50
<V-CONT (photosensitive drum surface potential contrast adjustment)>
<M> <S> <R> <P> <F>
DISP
FUNC
COUNTER
OPTION
TEST
ADJUST
VCONT-C
xxxx
VBACK-Y
xxxx
VCONT-M
xxxx
VBACK-M
xxxx
VCONT-Y
xxxx
VBACK-C
xxxx
VCONT-K
xxxx
VBACK-K
xxxx
V-CONT READY READY
Settings range
0~99
Unit:RX, DX=0.11mm (approx.) RY, DY=0.06mm (approx.)
(Standard: RX, DX=0 RY, DY=0)
remarks For this mode, you must have finished:
1. Adjusting the original stop position and
2. Adjusting the horizontal registration.
Note 1: You must enter the appropriate value whenever you have replaced a PCB or
initialized a RAM; record any new values on the service label for this pur-
pose.
F00-300-13
VCONT-C/M/Y/K
Indicates the present value of the target contrast potential.
VBACK-C/M/Y/K
Indicates the present value of de-fogging potential.