Technical information

COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-34
<RF-INF (RDF state)>
<M> <S> <R> <P> <F>
DISP
ADJUST
COUNTER
FUNC
OPTION
TEST
ERROR JAM
DOC-1 DOC-2 DOC-3 DOC-4
READY READY USER
RF-INF
xx
xx
xx
xx
xx xx
STATUS-1 STATUS-2 STATUS-3 STATUS-4
xx
xx
xx xx
F00-200-15
STATUS-1/2/3/4
For R&D
DOC-1/2/3/4
For R&D
ERROR
Indicates the error code sent by the RDF controller PCB.
01H:equivalent of E401
02H:equivalent of E402
03H:equivalent of E403
04H:equivalent of E404
05H:equivalent of E405
06H:no corresponding error
07H:equivalent of E411
11H:equivalent of E411
21H:equivalent of E400
JAM
Indicates the jam code sent by the RDF controller PCB.
See the details section in service manual of RDF.
ALARM
Indicates the alarm code sent by the RDF controller PCB.
01H:re-circulating bar idle rotation
02H:not used
03H:separation failure
04H:separation skew
05H:not used