Technical information
COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-28
Address Connector Description Remarks
804008 0 – for factory adjustment –
1 – for factory adjustment –
2 – for factory adjustment –
3 – for factory adjustment –
4 – for factory adjustment –
5 – for factory adjustment –
6 – for factory adjustment –
7 – for factory adjustment –
80400A 0 – for factory adjustment –
1 – for factory adjustment –
2 – for factory adjustment –
3 – for factory adjustment –
4 – for factory adjustment –
5 – for factory adjustment –
6 – for factory adjustment –
7 – for factory adjustment –
80400C 0 – transfer current (C) ON ON:1
1 – transfer current (C) UP UP:1
2 – transfer current (M) ON ON:1
3 – transfer current (M) UP UP:1
4 – transfer current (Y) ON ON:1
5 – transfer current (Y) UP UP:1
6 – transfer current (Bk) ON ON:1
7 – transfer current (Bk) UP UP:1
80400E 0 – primary bias (C) ON) ON:1
1 – primary bias (M) ON ON:1
2 – primary bias (Y) ON ON:1
3 – primary bias (Bk) ON ON:1
4 – separation AC bias ON ON:1
5 – blank pulse enable ON:1
6 – stray toner blocking high-voltage ON ON:1
7 – transfer,separation,pre-fixing enable ON:1
804010 0 – developing bias AC (C) ON ON:1
1 – developing bias AC (M) ON ON:1
2 – developing bias AC (Y) ON ON:1
3 – developing bias AC (Bk) ON ON:1
4 – developing bias DC (C) ON ON:1
5 – developing bias DC (M) ON ON:1
6 – developing bias DC (Y) ON ON:1
7 – developing bias DC (Bk) ON ON:1