Technical information

COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-28
Address Connector Description Remarks
804008 0 for factory adjustment
1 for factory adjustment
2 for factory adjustment
3 for factory adjustment
4 for factory adjustment
5 for factory adjustment
6 for factory adjustment
7 for factory adjustment
80400A 0 for factory adjustment
1 for factory adjustment
2 for factory adjustment
3 for factory adjustment
4 for factory adjustment
5 for factory adjustment
6 for factory adjustment
7 for factory adjustment
80400C 0 transfer current (C) ON ON:1
1 transfer current (C) UP UP:1
2 transfer current (M) ON ON:1
3 transfer current (M) UP UP:1
4 transfer current (Y) ON ON:1
5 transfer current (Y) UP UP:1
6 transfer current (Bk) ON ON:1
7 transfer current (Bk) UP UP:1
80400E 0 primary bias (C) ON) ON:1
1 primary bias (M) ON ON:1
2 primary bias (Y) ON ON:1
3 primary bias (Bk) ON ON:1
4 separation AC bias ON ON:1
5 blank pulse enable ON:1
6 stray toner blocking high-voltage ON ON:1
7 transfer,separation,pre-fixing enable ON:1
804010 0 developing bias AC (C) ON ON:1
1 developing bias AC (M) ON ON:1
2 developing bias AC (Y) ON ON:1
3 developing bias AC (Bk) ON ON:1
4 developing bias DC (C) ON ON:1
5 developing bias DC (M) ON ON:1
6 developing bias DC (Y) ON ON:1
7 developing bias DC (Bk) ON ON:1