Technical information
COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-23
Address Connector Description Remarks
80000F 0 PS12 transfer belt lifter sensor 1 UP:01
1 PS13 transfer belt lifter sensor 2 DOWN:10
2 PS17 transfer belt front end sensor 1 detected: 0
3 PS18 transfer belt rear end sensor 2 detected: 0
4 PS19 transfer belt front end sensor 3 detected: 1
5 PS20 transfer belt rear end sensor 4 detected: 1
6 – not used –
7 PS10 transfer belt cleaning web rotation sensor repeat 1 and 0 as
rotating
800010 0 M35 registration motor pulse count count end: 1
1 M13 transfer belt swing motor pulse count count end: 1
2 M23 duplex paper guide motor pulse count count end: 1
3 – not used –
4 – for factory adjustment –
5 – for factory adjustment –
6 – image position correction CCD shutter (front) open: 1
7 – image position correction CCD shutter (rear) open: 1
800011 0 – for factory adjustment 00;GDD
1 – for factory adjustment 01;GDE
2 – not used –
3 – not used –
4 – not used –
5 – not used –
6 – not used –
7 – not used –
802000 0 – CPU leading edge signal ON:1
1 – for factory adjustment –
2 – for factory adjustment –
3 – for factory adjustment –
4 – auto shut-off ON:1
5 – external PCB rest rest: 0
6 – 24 VDC remote ON:1
7 – phsync enable enable: 1
802001 0 – for factory adjustment –
1 – for factory adjustment –
2 – for factory adjustment –
3 – for factory adjustment –
4 – all-night power supply switch
after power SW-ON: 1
5 TH12 environment sensor low humidity: 0
6 – buffer unit power supply remote ON;G0
7 – flicker PCB control signal ON;G0