Technical information

COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-15
<M> <S> <R> <P> <F>
ADJUST
COUNTER
OPTION
TEST
DENS
FUNC
DISP
xxxx
xxxx
xxxx
xxxx
DENS-S-M
SGNL-S-M
REF-S-M
SGNL-D-M
2/3
xxxx
xxxx
xxxx
xxxx
DENS-S-C
SGNL-D-C
SGNL-S-C
REF-S-C
xxxx
xxxx
xxxx
xxxx
DENS-S-Y
SGNL-S-Y
REF-S-Y
SGNL-D-Y
xxxx
xxxx
xxxx
xxxx
DENS-S-K
SGNL-D-K
SGNL-S-K
REF-S-K
F00-200-07
DENS-S-C/M/Y/K
Indicates the density of the pattern on the drum (each color) in reference to
the target value.
Remarks Normal if between -40 and +40.
SGNL-S-C/M/Y/K
Indicates the measurement (AD conversion value) of the density of the
toner on the drum (each color).
Measurements are taken for each copying run.
Remarks For C, M, and Y, normal if between 640 and 850 (CMY).
For K, normal if between 192 and 389.
REF-S-C/M/Y/K
Indicates the measurement (AD conversion value) of the SALT reference
signal (each color).
Measurements are taken for each copying run.
Remarks For all colors, normal if between 464 and 544.
SGNL-D-C/M/Y/K
Indicates the measurement of the light reflected by the photosensitive drum.
Remarks For C, M, and Y, normal if between 380 and 900.
For K, normal if between 300 and 720.