Technical information

COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-14
<DENS (developer density)>
<M> <S> <R> <P> <F>
ADJUST
COUNTER
OPTION
TEST
DENS
FUNC
DISP
xxxx
xxxx
xxxx
DENS-M
xxxx
xxxx
xxxx
DENS-Y
SGNL-Y
REF--Y
SGNL-M
REF--M
xxxx
xxxx
xxxx
DENS-C
SGNL-C
REF--C
1/3
F00-200-06
DENS-C/M/Y
Indicates the discrepancy of the density of the developer on the developing
cylinder (each color) in reference to the target value in %.
+: Darker than target value.
–: Lighter than target value.
The value is the result of computations based on SGNL and REF stored un-
der ATR-INIT and SGNL and REF on the screen.
Remarks Unit: 0.1%
Normal if between -20 and + 20.
SGNL-C/M/Y
Indicates the measurement (AD conversion) of the current density of the
developer (each color).
Measurements are taken for each copy run.
Remarks Normal if between 700 and 912.
REF-C/M/Y
Indicates the measurement (AD conversion) of the reference signal (each
color).
Measurements are taken for each copy run.
Remarks Normal if between 377 and 848.