CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
5-136
4.1.26 E100
a.E100-xx01
Laser shutter
1) Is the operation of the laser shutter normal?
NO: Replace the faulty part.
DC power supply PCB 1 (lower)
2) Is power present at J2101 on the DC controller PCB?
J2101-1 (+) — J2101-4 (–): 5V
J2101-8 (+) — J2101-9 (–): 8V
J2101-7 (+) — J2101-8 (–): –12V
NO: Check the wiring; if normal, replace the DC power supply PCB 1
(lower).
Video controller PCB
Laser driver PCB
3) Is there a fault in the connection between the video controller PCB
and the laser driver PCB of the every color?
C J2106 — J3002C
J2107 — J3001C
M J2108 — J3002M
J2109 — J3001M
Y J2110 — J3002Y
J2111 — J3001Y
Bk J2112 — J3002K
J2113 — J3001K
YES: Re-connect it.
Laser exposure system
4) Is the laser power normal?
NO: Adjust it. If output is absent, replace the laser unit.
BD unit
Laser driver PCB
5) Clean the light-receiving face of the BD unit. Is the problem cor-
rected?
YES: End.
NO: Replace the following parts in the order indicated:
• BD unit
• Video controller PCB
Memo
You can find out whether the cause of ‘E100’ has been removed or not by
executing ‘FUNC > EPC > EPC’.