Technical information

COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
5-86
Optical path
15) Clean the standard white plate, scanning lamp, and reflecting lamp
cover mirror. Is the problem corrected?
YES: End.
16) Remove the CCD cover, and clean the surface of the CCD with a
blower brush. Is the problem corrected?
YES: End.
NO: Replace the CCD unit.
Pre-exposure lamp, Optical path (dirt)
17) Does the pre-exposure lamp have a fault?
YES: Remove the cause, and replace the part.
NO: Clean the bending mirror and the folding mirror.
Work on the Photosensitive Drum and Cleaning Blade
Clean the photosensitive drum with a flannel cloth coated with toner. You need not
replace the photosensitive drum if it is free of toner cake and its surface is free of
scratches.
Clean the cleaning blade with lint-free paper. You need not replace it if its edge is
free of scratches. Thereafter, put lubricant on lint-free paper, and coat the edge of the
cleaning blade evenly with lubricant.
Memo
If the lubricant is not even, the copies may carry white, vertical lines.
Limit the application to the edge of the blade, i.e., where it will come
into contact with the drum.
Do not rub the edge with force. Tap lightly over the edge to avoid damage.
Start from the top to the edge face as if to let the lubricant collect along
the line that will come into contact with the drum.
F05-304-01