CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
5-53
Taking Measurements
1) Start service mode.
2) Select ‘NIP-CHK’ of ‘FUSER’ under ‘FUNC’.
3) Select ‘NIP-CHK=1’.
4) Press the Start key to execute. (The operation will stop automatically.)
5) Measure the dimensions indicated in F04-203-02 as a, b, and c.
2.9.3 Adjusting the Mounting Position of the External Paper Delivery Unit
Guide Plate
1) Remove the left cover.
2) Open the front cover.
3) Pull out the fixing unit mount to the
position where the front side plate of
the external delivery paper unit and the
section A of the guide plate [1] overlap
each other.
F05-209-02
4) Loosen a screw [2] for the guide plate.
The guide plate [1] should be pushed in
while it is being pushed to the front side
plate of the external delivery unit [3].
5) Tighten the screw [2] for the guide
plate.
[3]
[A]
[2]
[1]
View
View