Technical information

COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
5-29
2.5.3 When Replacing the Photosensitive Drum
1) After replacing the cleaning blade, ap-
ply lubricant.
2) Clean the plastic film [1] under the pro-
cess unit mount with lint-free paper.
F05-205-07
3) Install the photosensitive drum.
4) Install the drum protection sheet.
5) Install the process unit, and install the
process unit mount.
6) Ready the copier, and turn on the power
switch.
7) Execute ‘auto gradation correction (full
correction)’ in user mode.
[1]
[1]