Technical information
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
5-24
2.4.2 Points to Note When Handling the Primary Grid Plate and the Primary
Charging Wire
Do not clean the primary grid plate or the
primary charging wire. If image faults (un-
even density) occurs, replace the part.
2.5 Developing Assembly-Related Parts
2.5.1 Replacing the Developer
1) Insert the door switch actuator into the
door switch assembly.
2) Turn on the power, and insert and turn
the control key.
3) Start service mode, and select ‘FUNC >
IN-STALL’.
4) Select the 2nd screen, and set ‘LSNS-
KIL’ to ‘1’.
5) Select ‘0’ by executing ‘ADJSUT >
PASCAL > PASCAL’.
6) Wait until warm-up ends.
7) Lift the hopper assembly to the topmost
position. (At this time, the locking
mechanism will turn on automatically.
Make a visual check of the hopper as-
sembly to make sure that the hopper as-
sembly is locked.)
8) Install the hopper retaining fixings (left,
right).
9) Release the hopper assembly, and move
the assembly down to where the retain-
ing fixings are located.
F05-205-01
Hopper assembly
Hopper retaining
fixing
Lock