10) Using two screws [10], fit the metal fix-
ing [10] of the scanner cable to the No.
1 mirror mount through the angular
hole in the side plate.
F05-202-08
F05-202-09
11) Remove the mirror positioning tool.
12) Fully tighten the four screws [7] loos-
ened in step 6.
REF.
You need not adjust the cable
tension.
1. Check to make sure that the
scanner cable is not twisted
or has not ridden over the
pulley.
2. Move the No. 1 mirror
mount and the No. 2 mirror
mount by hand to make sure
that they move smoothly; at
this time, take care not to
touch the reflecting plate.
[10]
[11]
[10]
[11]