e.Removing the Feed roller (reversal confluence)
1) Remove the rear cover.
2) Remove heater reversal inlet roller. (See
d. above.)
3) Remove the tension spring [1], and re-
move the four screws [2]; then, detach
the buffer pass motor [3] together with
its mounting base.
F02-907-21
4) Open the front cover.
5) Pull the retaining handle to the front,
and push up the retaining unit. (See
F02-907-17.)
6) Remove the E-ring [4], washer [5], and
bearing [6] at the front.
F02-907-22
[4]
[6][5]
[2] [1]
[2]