Technical information
2-230
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
CHAPTER 2 NEW FUNCTIONS
9.7.2 Feeding System
a.Removing the Upper Curl removing Roller
1) Open the front cover.
2) Remove the two screws [1], and detach
the retainer handle [2] together with the
handle support base [3].
F02-907-02
When mounting the retaining
handle, be sure to fit the pin [4]
on the slide shaft with the cut-
off in the handle.
F02-907-03
[1]
[3]
[2]
[4]