Technical information
2-150
CHAPTER 2 NEW FUNCTIONS
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
7 Externals and Controls
7.1 Outline of the Externals and Controls
The major difference is the addition of various fans, fuse PCB, and download function.
The rest are the same as the externals and controls of the CLC1000 Series machines.
7.2 Differences in the Externals and Controls
Unit/location
Fan
Leakage breaker
Holding tray heater
Fixing oil heater
Fuse PCB
Download connector/
switch
Differences from
CLC1000 Series
Addition of the following
General exhaust fan (FM21, 22,
23)
Laser scanner motor cooling fan
(FM24)
Pickup cooling fan (FM26, 32)
Exhaust lower cooling fan
(FM27)
Reversing assembly exhaust fan
(FM28, 29, 30, 33)
Fixing heat exhaust fan (FM31)
Delivery cooling fan (FM34)
Pre-fixing exhaust fan (FM35,
36)
Use of a leakage breaker
Elimination of the holding tray
heater
Addition of a fixing oil heater
Addition of a fuse PCB
Addition of a download function
Addition of a download connec-
tor/switch
Purpose
To review the flow
of air to enable
higher speed.
To improve safety.
To accommodate
the use of a
stackless duplex
system.
To ensure a specific
amount of fixing
oil.
To improve the pro-
tection mechanism.
To accommodate
the use of a flash
memory for the DC
controller PCB and
the reader control-
ler PCB.
Reference
7.3 “Fans”
7.4 “Power Supply”
7.4 “Power Supply”
7.4 “Power Supply”
7.4 “Power Supply”
7.5 “Downloading”
T02-702-01