Technical information

2-84
CHAPTER 2 NEW FUNCTIONS
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
e.Removing the Transfer Cleaning Web
1) Disconnect the connector [1]; then,
while pushing down the pressure arm
[2], lift the web assembly [3] to detach.
F02-405-82
2) After removing the resinous e-ring [4]
and the cleaner blade support shaft [5],
detach the web fixing bushing [6].
F02-405-83
[1]
[2]
[3]
[4] [6]
[5]
3) Lift the cleaning belt detection lever [7]
on the front side of the cleaning belt as
shown in the figure. Then pull the trans-
fer cleaning web [8] down to the point
where the figure F02-405-85 indicates,
and remove it upward.
F02-405-84
[7]
[8]
F02-405-85