Service manual
3. Servicing
3-1 Advisory for Replacement of Service Part (also for disassembly and assembly)
Replacing Service Part Note for replacement*1
Adjustment
/Setting up
Verifying operation
MAIN PCB ASS’Y
(FE2-0205-000)
Disconnect the power
cord,leave the unit about 1
minute (to discharge the
stored charge of the
capacitor) and
dismount the part (to
prevent MAIN PCB ASS’Y
broken)
Enforce
scan operation
CARRIAGE ASS’Y
(FE2-0206-000)
Be careful not to touch
mirrors or CCD PCBs.
Enforce
scan operation
PLATEN GLASS ASS’Y
(FE2-0201-000)
Be careful not to put dirt
or fingerprint on the
document glass.
Enforce
visual inspection
1:Note for entire work
Have a careful look on the wiring arrangement of flexible cable and harness, and
connection of connectors. [Refer to 3-2 Instruction for Servicing (1) Wiring arrangement
of flexible cable and harness, and connection of connectors]
1 - 3