2. Service Troubleshooting by Symptom
2-1 Service Troubleshooting by Symptom
symptom Action Remarks
Unit does not turn the power on
Spontaneously shuts down right
after turned on
Replace AC ADAPTER
or replace
MAIN PCB ASS’Y
Carriage does not operate Replace MOTOR ASS’Y
or replace
MAIN PCB ASS’Y
Acoustic noise Eliminate the foreign substance
or replace MOTOR UNIT
or replace
MAIN PCB ASS’Y
or replace
CARRIAGE ASS’Y
Malfunction
Scanning lamp does not light up
ReplaceCARRIAGE ASS’Y
or replace
MAIN PCB ASS’Y
Blurred image Clean PLATEN GLASS ASS’Y
or replace
CARRIAGE ASS’Y
or replace
MAIN PCB ASS’Y
Solid vertical line Clean PLATEN GLASS ASS’Y
or replace CARRIAGE ASS’Y
Solid horizontal line Check the connection with PC
or replace USB cable
or replace
MAIN PCB ASS’Y
Faulty scanned image
Faulty color reproduction
Replace
MAIN PCB ASS’Y