REF. NO. 3.20401 EXPLODED VIEW of CANON CINE CANON 8 (33-2575 35-2760 33-2781 8 xi Xi-170357, 33-2682 4 xi-143429 XB2-4O113 33-2653 oP 33-2650 SCALE 1-20 CANON CAMERA CO., INC.
REF. NO. 3-20401 EXPLODED VIEW of CANON CINE CANON 8 33-2B14 @ ROG OIE © | §7-7120 39-0058 & No | 3-seei 5 ever ty 3017 ® #96 30057, w $ X21-20507, T ta #24 R008, 25 A-Gi146 & 3 on YOU 360 © p X32-50234 x-eo030r © @ x50 38-0075 LACE 1.2.0 CANON CAMERA CO. ING.
REF. NO. 3.20401 EXPLODED VIEW of CANON CINE CANON 8 21170886, 6B ® 32-2695 « 33-2707 No x15-70158 xgz-4101 (ame 33-262 BEG r i 33-2178 Op-233430 30-9265 % x11-170267 a SCALE 1-2.0 CANON CAMERA CO. INC.
REF. NO. 3-20401 EXPLODED VIEW of CANON CINE CANON 8 33-2705 g xis-200387 \33-2625 i L X1-17G2ST, SN 3 @ 19-9251 33-2624 &. (33-2783 Res X12-502132 2 w 33-9255 NE 6 2776 @ 13-4248 = 33-9263 332564 . “@ 33-2628 “ Sd 2776 Te vy BEN Gy ease @ sar 2 38-0064 Boreas “Ea xor-203080 or 30-9259 39-9261 ® 33216 a-418s X26-170258 aR = 38-0063 ax-s052e (40158 eg A xe soe er X32-4011 97-709 33-2603 SCALE 1-2.0 CANON CAMERA CO. INC.
Disassembling Method «vices uiernneerneriorsnarsssoaisanreensosnorsn Replacing Method Shutter Release Device Filming Motor Zoom Lens Exposure Meter Viewfinder ...
Work Repair Manual P. 1 1. Removal of focusing lens 2. Removal of CdS aperture ring 3. Removal of manual knob 4. Removal of cover screw 5. Removal of cover Repair Manual P, 2 1. Removal of shutter release device 2, Removal of mater 3.
4, Removal of exposure meter Repair Manual P, 3 1. Removal of viewfinder 2. Removal of threading plate Repair Manual P, 4 1. Removal of partition 2, Removal of battery checker 3. Removal of {ilm counter Unsold er yellow-orange cord 1. unsold er yellow cord X21-200358x3 Screw x 3 X96-202157x3 _ 3 11 Screw % 3 undersold yellow cord and white cord remove 24 exposure meter unit 3. X21-170308x2 33-2707 1.
Repair Manual PP. 5 1. Removal of ¥21-170458 X32-501832 33-2726 1. governor Screw Washer Insulator 33-2726 ¥91-172436 33-2726 Insulator Insulator —unsold er yellow-orange and red 2.
Replacing of Shutter Release Device Work Method 1. Disassembling Refer to Disassembling Method "Removal of Shutter! method Release Device’. When removing, loosen a left screw bottom and slightly lift up for easy removal. 2. Inspection Inspect the insulation parts. 3. Attaching method 1, Attach the motor to the shutter release device. Adjust so that the gears have appropriate play and apply liquid molybdenum. 2.
Replacing of Filming Motor Work Method I. Disassembling Refer to Disassembling Method "Removal of Motor! method 2. Inspection I. Motor gear assembly _ Gear Spring ar Sl Nuc Fig. [Washer Washer Retaining Washer 2. Inspection 2-1 Pass 4V {DC) of electricity through the motor and measure with the current meter. The motor is ta be considered as good if the meter indicates around 50mA Matt. 2-2 Next, revolve the motor while holding the gear and measure the slip current.
Work Disassembling method Inspection Attaching method and notes Adjusting method Replacing of Zoom Lens Method Refer to Disassembling Method "Removal of Zoom Lens’, 1. Check to see that there are no stains or dust on the unit parts, 1. Match the cut-off part of the helicopter in the screw hole and then tighten the screw. 1-1 Attach so that it does not touch the meter needle. 1-2 Attach so that the viewfinder prism does not touch the body. 1. Focus adjustment Use universal two axis collator {130mm & 300mm}.
Make the upper frames of the chart and the frame parallel while looking into the viewfinder. 2-2-2 The left and right side deviations of the frame can be corrected by moving the zoom lens mount in the direction of the lens circumference. 2-2-3 The top and bottom deviations of the frame can be corrected by slanting the viewfinder prism forwards or backwards. 2-2-4 A slanted image is corrected by slanting the viewfinder prism to either left or right.
Replacing of Exposure Meter Work Method 1, Disassembling Refer to Disassembling Method "Removal of Exposure method Meter, The relay lens is to be kept detached. 2, Inspection I. The blade should open and close without slipping when operated manually. 3. Attaching method 1. Attaching of exposure meter and notes 1-1 Attach a relay lens onto the new meter. 1-2 Close the aperture manually, and while being careful of the needle, attach it onto the body.
of a standard body obtained with an inspection device for Cine Castanet Meter. Place the body on the exposure meter inspection device, open the shutter, attach the standard CdS, install the mercury battery and hold the contact point with a clipper. 2. Adjusting 2-1 Set the manual knob at auto. Set ASA at 10 and the frame speed at 16, Apply F5, 6 brilliance of 1536 CD? and adjust so that the resistance value comes within the limit. When it is outside the limit, make the following adjustments.
Turn with a lever driver When the above adjustments have been made, repeat the adjustments from 2-1. Check to see whether the needle comes within the red mark on the left at ASA 320, 16 frame speed and 1700 cd/m?. If not, turn the lever of hair spring sightly to the left and repeat adjustments from 2-1. Increase the brilliance and put the needle into the red mark on the left, then suddenly drop the brilliance to 0 and check to see whether the needle enters the red mark on the right within 5 seconds.
Work 1. Disassembling method 2. Inspection 3. Attaching method 4. Adjusting method Replacing of Viewfinder Method Refer to Disassembling Method "Removal of 1, There should be no dust, scratches or stains on the frame. There should be no shadow of the field-of-view. Attach so that the lens on the tip of the viewfinder does not touch the needle. Temporarily set the frame in an approximately parallel position. Set the viewfinder towards the side of the viewfinder holder {pack side}. Fig.
Replacing of Battery Checker Work Method I. Disassembling Refer to Disassembling Method "Removal of Battery method Checker", 2, Inspection 1. Check with low voltage meter for direct current. It should be on the dividing line between ved and white and on the dividing line between blue and white at 3,8Y 20. 1V. Red , ~3.04Y = 3 6V Fig. 13 White—] Ble VOLT = 3.9 3. Attaching method 1. Tighten with nut. and notes 2. Solder the lead wire.
Work Disassembling method Inspection Attaching method and notes Adjusting method Replacing of Film Counter Method 1, Refer to Disassembling Method "Removal of Film Counter’. I. The needle should move smoothly without jerking. 1. After tightening with nut, check the movement of the needle once more and then attach the spring. I. Insert film counter gauge -2 into the supply spindle saith and check to see whether the needle comes within the index below. 2.
Replacing of Governor Work Method 1, Disassembling Refer to Disassembling Method "Removal of Governor method 2. Inspection 1. The auxiliary contact point should come into contact first when the needle is slowly pressed. The auxiliary contact point is made weak by cutting an elliptic shape out of the pendulum plate, Te 2 i Needle Fig. 16 = 2. When the pendulum is slowly revolved with the finger it should revolve smoothly without eccentricity. 3. Attaching method 1. Tighten with screw.
2. 12-frame adjustment 15. Long hole Fig. speed up = —=To slow down 2-1 Set the speed dial at 12 frames. 2-2 Adjust by moving the eccentric cam to left and right. Recheck l-frame speed. 3. 24-frame adjustment 3-1 Set the speed dial at 24 frames. 3.2 When screw (3) of Diagram 17 is tightened the filming speed is seeded up, when loosened it is slowed down. Tighten the other screw to the degree where the filming speed does not change. {Auxiliary contact plate.} 3-3 Recheck both 16-ramie and 12-frame speeds, 4.
MOVING PARTS 1, 2, Does not move Revolution is unstable TROUBLE, CAUSE & REMEDY 5, Battery has been used up Check with new battery. Faulty connection with battery Push the battery towards the pole. Check with new battery. Check and adjust the pole spring and the dejection. Faulty connection with pole Remove rust or glue from pole or replace. Check with new battery. Particularly check the soldered parts. Faulty connection with switch Remove the cover, clasp the switch and press the release.
FILM FEEDING I. Faulty film 1. feeding 2. Faulty take-up I. FILM COUNTER 1, Film counter 1. does not move cult film 1. counter §, F position 2. 3. Counter arm does L not lock, unstable FILMING 8 1, Faulty filming speed L. Big pressure on pressure plate and side load spring Pressure plate. 50% 10g Side load spring, 30 « 40g Should be within the above limits {measure with Tension gauge 0-300g Convex Co.) Faulty take-up spindle Take -up spindle 45% 10 g-cm Adjust coil spring.
2. Filming speed does not change 3. Faulty single frame 4, Running does not stop VIEWFINDER 1. Faulty distance 2. Faulty field-of-view 3. Out of focus around outer edge of viewfinder 4. Loose focus helicopter EXPOSURE METER 1. Exposure meter does not move Governor tightening screw is loose Tighten screw and glue. Loose speed dial Bend spring washer or replace. Or just re tighten screw.
2. Exposure meter catches 3. Exposure meter does not move manually 4, Auto accuracy is bad 5. Exposure meter moves at "OFF rr FOCUS AND ZOOMING 1. Faulty focus 2. Zooming catches OTHERS 1. Checker does not ve a Faulty contact with safety switch Check attachment position of switch cam, Meter is cut off Check and poles of meter with tester, CdS is cut off Check both ends of CdS with tester, If disconnected, replace meter. Dust between meter coil and magnet Remove dust or replace.
2. Short circuit Rewire circuit, 3. Needle catches Replace or adjust by bending needle, 2. Light leaks 1. Side cover if due to the dejection of light shield, replace light shield. 2.
INSPECTION STANDARD 1, Exterior appearance 1-1 1-3 Painting and plating of exterior surface 1) Scratches and unevenness on plating 2} Stains on plating 3) Dents 4} Deformations 5} Scratches on paint or base metal 6) Paint pealing off 7) Scratches or dullness on acrylic window parts 8} Scratches or dents on name plate Painting and plating of interior surface 1} Scratches and unevenness on plating 2) Scratches on paint or base metal 3) Paint peeling off 4} Scratches or dents on pressure plate Plate attachment
wl Assembly 2-1 Height difference and gap of joints between top cover, body case, side caver and front cover 2-2 Manual aperture knob revolution torque 2-3 Zooming ring revolution torque 2-4 Helicon torque 2-5 Weight of film speed setting dial 2-6 Long helicopter 2-7 Play of index vying 2-8 Aligning of focusing ring scale 2-9 Zooming ring dial position Viewfinder 3-1 Field of view 3-2 Adjusting range of eyesight 3-3 Magnification 3-4 Parallax 3-5 Frame and tumble of image 3-6 Zooming deviation 3-7 Ghost Fil
5-5 Governor 5-6 Strength of feed claw 5.
9-4 Safety switch 10. Battery checker 10-1 Button stroke 10-2 Needle position 11. Shooting lens 11-1 Light shaft 11.2 Focus 11-3 Resolution power 11-4 Shadow 12. No light leakage 27 Motor circuit and EE circuit should completely open at OFF position Indicator needle should move Refer to 5-1 on filming speed + 0,02 against standard lens Over the figures in chart below at projection distance of 25 mm Center{ 100 75 50 25 160 75 50 25 Should be no shadow at minimum aperture and very close distance.
TESTING EQUIPMENT Use Focus Shutter Field of View Exposure Meter Film Counter SPECIAL SCREWDRIVER TOGA 27-5167 TOGA-27-8168 Jal CANON SERVICE TOOL LIST CANON CINE CANON 8 (REFERENCE NO.