Specifications
Command Descriptions
2- 280
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
TRIGGER:A:PULSE:RUNT:THRESHOLD?
might return :TRIGGER:A:PULSE:RUNT:THRESHOLD:HIGH 2.00E+0;LOW
800.0E-3.
TRIGger:A:PULse:RUNT:THReshold:BOTh
Sets the value of both runt pulse signal thresholds. This command is equivalent
to setting Set to TTL or Set to ECL in the Run t Trigger menu’s Thresholds
side menu item.
Trigger
TRIGger:A:PULse:RUNT:THReshold:BOTh { TTL | ECL }
TTL sets the upper (high) threshold value to 2.0 V and the lower threshold value
to 0.8 V.
ECL sets the upper (high) threshold value to --1.1 V and the lower threshold value
to --1.5 V.
TRIGGER:A:PULSE:RUNT:THRESHOLD:BOTH TTL
sets the upper and lower runt pulse trigger threshold voltages to TTL voltage
levels.
TRIGger:A:PULse:RUNT:THReshold:HIGH
Sets or returns the runt pulse signal high threshold voltage value. This command
is equivalent to setting the threshold in the runt pulse Thresholds side menu.
Trigger
TRIGger:A:PULse:RUNT:THReshold:HIGH <NR3>
TRIGger:A:PULse:RUNT:THReshold:HIGH?
<NR3> is a floating point value with exponent that sets the runt pulse high
threshold voltage value.
TRIGGER:A:PULSE:RUNT:THRESHOLD:HIGH 1.8E0
sets the runt pulse high threshold voltage value to 1.8 volts.
Examples
Group
Syntax
Arguments
Examples
Group
Syntax
Arguments
Examples