User Guide

10
5 - TROUBLESHOOTING GUIDE
This section deals with some troubles, which can occur when using this fork. Possible causes are mentioned as well
as recommendations on how to possibly solve the problem.
Always read the following table before performing any fork fixing.
TROUBLE CAUSE REMEDIES
Oil leakage from the oil seal 1. Oil seal wear 1. Change oil seal
2. Scored stanchion tube 2. Change the tube and the
oil seal
3. Dirty seal 3. replace
Foot oil leakage 1. Foot valve OR damaged 1. Change the seal
2. Loose foot valve 2. Tighten the screw
3. OR of the compression 3. Change the seal
screw adjuster damaged
The fork is too soft under 1. Low oil level 1. Top up
any adjustment conditions 2. Broken spring 2. Change the spring
3. Too low oil viscosity 3. Use a different oil viscosity
The fork is too hard 1. Too high oil level 1. Restore the oil level
under any adjustment 2. Too high oil viscosity 2. Use a different oil viscosity
conditions
The fork has no reactions when 1. Inner rod pin blocked 1. Clean or change the rod
adjustment changes are made 2. Blocked compression 2. Disassemble and
screw adjuster clean
3. Oil with foreign bodies 3. Clean and change oil
4. Foreign bodies 4. Disassemble and
occluding damper valves clean
Decreased sensitivity 1. Sliding bushing wear 1. Change sliding bushing
2. Oil needs change 2. Change oil