Specifications
Table Of Contents

FIG 1.
*(FOR INSTALLATION INTO A
MASONRY/BRICK FIREPLACE)
HEATER SPECIFICATIONS
4
WIRING DIAGRAM
240 V MAINS PLUG
N
N
A
L
M
H
TH2
MOD1
MOD2
BLACK
WHITE
ORANGE
GREY
PURPLE
BROWN
BLUE
BLACK
BROWN
WHITE
BLUE
YELLOW/GREEN
8 WAY CONNECTOR
BLACK
BROWN
RED
RED
WHITE
RED
PRESSURE
SWITCH F3327
ROOM AIR FAN
NO
FUSE
BLUE
BLUE
ORANGE
GREY
PURPLE
YELLOW/GREEN
BLUE
MODULATING
VALVE F3691
COILS
1.5 AMP
ON/OFF
LW BRN / LW FAN
MED BRN / MED FAN
HIGH BRN / HIGH FAN
SHEATHED
CABLE
E
N
A
FLAME
SENSOR
SPARK
ELECTRODE
FUNCTION
CONTROL
MODULE
P/No. F3604
IGNITION MODULE
F3435
SWITCH
ROOM FAN - F3594
COMBUSTION
FAN - F3659
W
BLK
BRN
6 WAY CONNECTOR
6 WAY CONNECTOR
BLUE
4 WAY
F3663-6_B
NO
PRESSURE
SWITCH F3327
COMBUSTION FAN
POWER FLUE
WIRING DIAGRAM
COMMON
COMMON
4 WAY
25
Gas type:Natural or Propane gas, as indicated on data label
Gas consumption: 26.0 MJ/hr
Energy output: 5.98 kW
Enery star rating: 5.05 stars
Heater type: Gas space heater
approved to AS 4553:2008
Operating pressure: Natural gas: 0.75 kPa
(at burner high setting) Propane gas: 2.65kPa
Gas regulator: Integral part of controller
Min. inlet pressure: 1.13 kPa (NG)
2.75 kPa (Propane)
Fan: 3 speed
Controller: Electronic direct spark
Power requirement: 240 VAC 10 A
Power consumption: 90 VA maximum
Minimum cavity Height: 605 mm*
dimensions:Width: 700 mm
Depth: 485 mm
Optional accessories:
Glass front
Remote thermostat
Spacer kit
3 sided surround
4 sided surround
Console kit
The Cannon appliance is warranted against defects in materials and
Warranty service, which includes parts and labour for the replacement or
repair of defective parts, is available through the CANNON distributor.
(Details below or on page 24).
Consumers are responsible for service person’s travel outside normal
service areas (approximately seventy (70) kilometer radius from the nearest
Cannon dealer’s location), local transport costs, or any preventative
maintenance works as described in
Any product subjected to misuse, abuse, negligence, accident or alteration
will have its warranty voided. The defacement of serial plate will also void
warranty.
If installation is not carried out in accordance with manufacturer’s
instructions, this warranty may be void.
The customer must keep their “Tax Invoice” as proof of purchase of this
product and compliance certificate as proof of required installation.
workmanship for a period of two (2) years from its date of original
purchase, applicable only for residential use in Australia.
this manual.
Enter the details of the date installed and the Compliance Certificate
number in the appropriate area on the rear page of this manual.