Specifications
Operating instructions
Plug the power cord into the wall socket and turn on the
power to the heater (see figure 2).
Alternatively, switch on the isolation switch
and circuit breaker at the main switchboard if the heater has
fixed wiring.
Refrain from using an
extension cord.
User instructions
2
7
22
3
ON / OFF
LOW
MEDIUM
HIGH
Ignition module
Mounting bracket
Service Instructions - (Do not modify this appliance)
User controls, figure 3
When there is power available to the heater and
it is in the OFF or Standby mode, a red LED
located inside the ON/OFF button will flash
twice and will extinguish for approximately 3
seconds and then repeat this cycle
continuously.
?To turn the heater ON press the ON/OFF button
once.
?The LED will illuminate and stay lit but there will
be approximately 5 seconds delay before the
ignition system commences. On successful
ignition the heater will operate on Low Fire and
Low Fan for approximately 3 minutes then will
switch to selected setting (if already chosen).
?The LED will extinguish approximately 30
seconds following the ignition startup.
?Select the desired Heating level by pressing the
LOW, MEDIUM or HIGH button once as
required.
?LOW is LOW heat and LOW speed fan. HIGH is
HIGH heat and HIGH speed fan.
?To turn the heater OFF press the ON/OFF
button once. The burner will extinguish but the
fan will continue to operate for approximately 3
minutes.
?If the Ignition system fails to ignite or keep the
burner alight, press the ON/OFF button once to
turn off the heater. Wait at least 20 seconds
before attempting to turn the heater on again.
Remember that the fan will continue to operate
for approximately 3 minutes after the OFF
button has been pressed but you can turn the
heater ON again without having to wait for the
fan to stop operating.
?If there is an interruption to the power supply
the heater will fail safely and switch off. When
the power supply has been restored adopt the
20 seconds waiting rule before turning the
heater ON.
To replace the ignition module (device)
1. Unplug wire connectors from ignition module.
2. Remove module mounting bracket by removing mounting screw.
3. Using pliers bend tabs so that module can come away from the mounting bracket.
4. Replace ignition module and ensure that all wires are reconnected correctly.
General
1. Service work to be carried out by an authorised service person only.
2. Unplug from wall socket or turn off power at main switchboard if heater is hard wired.
3. Always shut off the gas supply and ensure that the heater is cool before commencing any
service operations.
4. Always check for gas soundness after servicing.
To replace the primary glass
1. Refer page 12 of the installation instructions. Fit the new glass.
Note: Ensure the inside surface of the glass is clean and free from finger marks.
To replace the gas control valve
1. Remove the fascia.
2. Unplug the cables from the gas control and disconnect the earth connection.
3. Disconnect the gas inlet (½" compression nut) connection at entry gas control and the
16mm nut at the outlet of the gas control.
4. Remove the three M3 screws from the cradle retaining the gas control.
5. Remove gas control valve from heater.
6. Replace gas control and check for gas tightness.
Note: check the gas pressure on high and low burner settings. Refer “gas control”,
pages 17 and 18.
29