Instruction manual
Cannon Fitzroy / Canterbury Inbuilt | 9
CANTERBURY INBUILT SPECIFICATIONS
Cannon Canterbury Inbuilt
FIG 4 Front View and Side View of Canterbury
Gas type Natural or Propane gas, as
indicated on data label
Gas consumption 26 MJ/hr input
Energy output 5.10 kW / 18.36 MJ/hr
Energy star rating 3.1 stars
Heater type Gas space heater approved to
AS4553:2008
Operating pressure Natural gas: 0.75 kPa (High)
/0.40 kPa (Low)
Propane gas 2.65 kPa (High)
/ 1.1 kPa (Low)
Gas regulator Integral part of controller
Min. inlet pressure 1.13 kPa (NG)
2.75 kPa (Propane)
Fan 3 speed
Ignition Electronic direct spark
Power requirement 240 VAC 10 Amp
switch socket
Power consumption 90 VA maximum
Minimum cavity
dimensions
Height 640mm*
Width 710mm*
Depth 359mm^*
Optional accessories • Safety mesh guard
• Remote thermostat
• Spacer kit
• 3 sided surround
• 4 sided surround
• Console kit
• Inbuilt flue kit
• Mock fireplace installation kit
Overall dimensions Refer to FIG 4
^Minimum depth for heater and flue adaptor.
Please Note:
• When installing into a mock fireplace a mock
fireplace installation kit must be used.
• The data label is located in the fan chamber.
Access by removing lower fan chamber fascia panel.
850 mm
655 mm
*For installation into a masonry/brick fireplace.
125 mm
41 mm
338 mm
630 mm
180 mm
600 mm