Instruction manual
8 | Cannon Fitzroy / Canterbury Inbuilt
FITZROY INBUILT SPECIFICATIONS
Gas type Natural or Propane gas,
as indicated on data label
Gas consumption 26.0 MJ/hr
Energy output 5.65 kW / 20.34 MJ/hr
Energy star rating 3.60 stars
Heater type Gas space heater approved to
AS 4553:2008
Operating pressure Natural gas 0.75 kPa (High)
/0.40 kPa (Low)
Propane gas 2.65 kPa (High)
/ 1.1 kPa (Low)
Gas regulator Integral part of controller
Min. inlet pressure 1.13 kPa (NG)
2.75 kPa (Propane)
Fan 3 speed
Ignition Electronic direct spark
Power requirement 240 VAC 10 Amp
switch socket
Power consumption 90 VA maximum
Minimum cavity
dimensions
Height 605 mm*
Width 700 mm*
Depth 409 mm^*
Optional accessories • Glass front
• Remote thermostat
• Spacer kit
• 3 sided surround
• 4 sided surround
• Console kit
• Freestanding kit
• Inbuilt flue kit
• Mock fireplace installation kit
Overall dimensions Refer to FIG 3
^Minimum depth for heater and flue adaptor.
Please Note:
• When installing into a mock fireplace a mock fireplace
installation kit must be used.
• The data label is located in the fan chamber.
Access by removing front fascia.
Cannon Fitzroy Inbuilt
FIG 3 Front View and Side View of Fitzroy
* For installation into masonry/brick fireplaces.