Data label Cannon USER INSTRUCTIONS INSTALLATION INSTRUCTIONS Stick copy of data label here! SERVICE INSTRUCTIONS Date installed: ........................................ Compliance Certificate No ......................... CANTERBURY INBUILT MODELS For service to this appliance or spare parts contact the CANNON distributor: Sampford IXL (spare parts) PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING THIS HEATER. Cannon Phone: 1300 727 421 Fax: 1300 727 425 email: service@sampfordixl.com.
Contents Contents Warranty ? 2 8. 3 Safety warnings ? What to do if you smell gas ? Warnings ? Standards 4-5 User instructions ? Operating instructions ? Cleaning ? Flame characteristics 6-8 Heater specifications 9. 16-17 Fuel bed and log installation Gas control ? Gas pressure point ? Gas pressure adjustment Installation tips 2 10-15 correct polarity. Do not use an extension cord. Check polarity in the electrical supply lead to appliance. • Check that the sense electrode is in the flame.
Trouble-shooting (Do not modify this appliance) To check the operation of the electronic (module) controller (Techrite ) you will require a digital multimeter with the functions to measure AC/DC voltage, continuity, resistance and micro-amps. Warranty The benefit conferred by this warranty are in addition to all other rights and remedies in respect of the product that consumers have under the Trade Practices Act and similar laws of the States and Territories.
Safety Warnings Please read this manual before installing and using the heater. To remove the heat exchanger What to do if you smell gas Please refer to manufacturer. Contact details page 24 of this manual. 1. Turn OFF the main gas supply. 2. Extinguish any open flame. 3. Open windows. 4. Do not touch electrical switches. 5. Do not use your telephone. 6. Call your gas supplier immediately from a neighbour’s phone. To replace the burner and spark/sense electrodes 3.
To replace the room circulation fan 1. Remove the lower front cover by unscrewing two M5 screws through the air intake slot. Refer page 13, figure 16, of the installation instructions. 2. Remove the screw retaining the bracket mounting the valve controls ( white box) Move the bracket and controls to the front of the heater. 3. Disconnect the fan plug from the plug carrier. Remove the two M5 wing nuts which locate the fan to the fan chamber underside. Lower fan from male thread. 4.
User instructions Service instructions (Do not modify this appliance) General Operating instructions 1. Service work to be carried out by an authorised service person only. 2. Unplug from wall socket or turn off power at main switchboard if heater is hard wired. 3. Always shut off the gas supply and ensure that the heater is cool before commencing any service operations. 4. Always check for gas soundness after servicing. 1.
Operate the heater on HIGH, MEDIUM and LOW burner settings. The flame should be stable with no lifting from the burner and the logs should glow after approximately 15 minutes of operation on HIGH burner. If the flame is unstable: • Check that the burner is located correctly. • Check that the glass front is located correctly and is against the sealing rope. • Check that the gas pressure is correctly adjusted. Cleaning All cleaning should be carried out when the heater is cold.
Heater specifications Gas pressure point Gas type: Note: The data plate is located on the fan chamber base, rear of the lower fascia. Natural or Propane gas, as indicated on data label Gas consumption: 26 MJ/hr input Energy output: 21.45 MJ/hr (5.96 kW) Energy star rating: 4 stars Heater type: Approved to AS4553:2008 Operating pressure: (at the burner) Natural gas: 0.75 kPa Propane gas: 2.65 kPa Gas regulator: Integral part of controller Min.
Installation instructions Advise the user in the operation of the heater 18. Refit the inner glass, making sure not to overtighten the screws. 1. This appliance is to be installed by an authorised service person only. 19. Refit the front glass surround. Ensure that the glass surround is replaced the correct side up. The rearward sloping frame must be at the top and the vertical ledge must be at the bottom. Refer figure 30. 2.
Log installation For installation onto a masonry or brick fireplace WITH a flue connection refer figure 11. For installation WITHOUT a flue connected referfigures 12 & 13. After installation of the heater/flue test the flue to confirm air vents are unobstructed. If an exhaust fan or other heating appliances are present switch them on. This is to test that there is no interaction between the CANNON heater and other appliances. Refer AS5601. 16. The burner is contained within the burner chamber.
Gas connection 13. Slide heater into the fireplace ensuring that gas inlet pipe is fed through the hole at the rear bottom RHS of the heater. Refer figure 22 and gas connection figure 24. Installation WITHOUT a flue connection. 20 22 - 14.With heater in position, flanges should be hard against masonry. Secure case flanges to masonry. Refer figure 23. 12 23 15. Connect incoming gas supply pipe to regulator. For inlet position see figure 24.
6. Prepare electrical and gas connections. Remove the lower front cover, see figure 16. A 10 Amp wall socket needs to be located within 1.5m of the heater. If using a power point in the chimney, route the plug and cord through cord access at lower LH side of rear panel. A grommet is fitted over the cord. Ensure that the grommet is located over the edges of the access hole. Refer figure 14. Hard (fixed ) wiring connection is to be carried out only by a qualified electrician. 18 14 7.