USER INSTRUCTIONS Cannon INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS Data label Attach copy of data label here! CANTERBURY FREESTANDING MODELS Date installed: ........................................................................................................ Compliance Certificate No .....................................................................................
Contents Notes Contents 2 Warranty 3 Distributor Safety warnings 4-5 What to do if you smell gas Warnings Standards User instructions 6-7 Operating instructions Flame characteristics Cleaning Heater specifications Installation instructions 8-9 10-15 Clearances Installation Gas connection Log installation Gas control Flue installation Installation tips Gas control 16-17 Gas pressure point Gas control adjustment Service instructions 18-19 General To replace primary glass To replace outer glass
Notes Warranty The benefit conferred by this warranty are in addition to all other rights and remedies in respect of the product that consumers have under the Trade Practices Act and similar laws of the States and Territories. We warrant this Cannon appliance to be free of defects in materials, workmanship and manufacturing to the original purchaser for 2 years, (10 years on the heat exchanger) from the date of original purchase.
Safety warnings Please read this manual before installing and using the heater. TROUBLESHOOTING 5 Confirm spark is produced when heater is turned on. 6 If no spark being produced. What to do if you smell gas 1. 2. 3. 4. 5. 6. Turn OFF the main gas supply. Extinguish any open flame. Open up windows and doors to remove any gas. Do not touch any electrical switches. Do not use your telephone. Call your gas supplier immediately from a neighbour’s phone. Warnings 1.
TROUBLESHOOTING-(DO NOT MODIFY THIS APPLIANCE) To check the operation of the electronic (module) controller (Techrite) you will require a digital multimeter with the functions to measure AC / DC voltage, Continuity, resistance and micro-amps. It is critical that the appliance is earthed and that the active and neutral are not reversed. Trouble shooting Guide for Ignition Controller ( Techrite) There is a green and red LED on the ignition controller. These act as diagnostic aids when ignition does not occur.
Service instructions User instructions (Do not modify this appliance) To replace the room circulation fan Operating instructions 1. Plug the power cord into the wall socket and turn on the power to the heater, see Fig 1. (The use of an extension cord is not recommended.) Fig 1. 2. For control lay-out refer to Fig 2. ON/OFF button When there is power to the heater but it is Off (or in standby mode) a red LED will flash intermittently behind this button.
Service instructions User instructions (Do not modify this appliance) General Flame characteristics 1. Service work to be carried out by an authorised service person only. 2. Unplug from wall socket or turn off power at main switchboard if heater is hard wired. 3. Always shut off the gas supply and ensure that the heater is cool before commencing any service operations. 4. Always check for gas soundness after servicing.
Gas control Heater specifications Note: The data plate is located on the rear of the removable pedestal front. Gas type: Gas consumption: Energy output: Energy star rating: Heater type: Operating pressure: (at the burner) Gas regulator: Min. inlet pressure: Natural or Propane gas, as indicated on data plate. 26 MJ/hr input. 21.45 MJ/hr (5.96 kW). 4 stars. Approved to AS4553:2008. Natural gas: 0.75 kPa. Propane gas: 2.65 kPa. Integral part of controller. 1.13 kPa (Nat Gas). 2.75 kPa (Propane). 3 speed.
Gas control Heater specifications 1. Gas control layout is as indicated in Fig 1. Pressures for ‘Burner full on’ and ‘Burner low flame’ are HIGH BRN / HIGH FAN RED BLACK MODULATING VALVE F3691 BLACK COMMON NO PRESSURE SWITCH P/No. F3327 RED MOD1 WHITE 8 WAY CONNECTOR RED IGNITION MODULE F3434 BLUE BLACK WHITE E N A MOD2 RED TH2 FUNCTION CONTROL MODULE P/No.
Installation instructions Flue installation Overall dimensions: Refer to Heater Specifications on Page 8. 1. This appliance is to be installed by a suitably licensed person only. 2. This appliance shall be installed in accordance with these manufacturer’s installation instructions, local gas fitting regulations, municipal building codes, electrical wiring regulations, and AS5601 the Australian Standard for gas installations. Refer also AS5601 for gas pipe sizing tables.
Installation instructions Flue installation This heater is a flued appliance. It must be properly connected to a flue system in accordance with the latest edition of the Gas Installation Code, AS 5601. only and no more than two in If elbows are required, we recommend 45? the total flue run, there should also be a minimum of 250mm straight flue section in between bends.. If practical, locate the heater in a position to minimise the need for elbows. There must be at least 1.
Installation instructions Installation instructions Position the four individually numbered logs in the following order on the burner head as shown in figures 6 - 9. The male locating pins in the burner head must engage with corresponding holes in the individual logs. a) Place log No.1 onto the two front left pins of the burner head, ensuring that the largest “charcoal charring”section is facing to the front of the burner base. Note: This Log can fit the wrong way around. Refer Fig 6. Fig 6.