User`s guide

Section 2 MultiMux Operation and Installation 6
2.2 Datalogger Connection
The MultiMux is connected to the CR10/CR10X Controller or MultiLogger Mux Terminal Board (or ML
MUX TB) using the screw terminals on the terminal board.
The screw terminal block located on the bottom of the terminal board has the
following connections:
The table below lists the connections for the screw terminal block.
If using the MultiSensor Interface with your CR10 or CR10X then connect from the 10-pin connector
(using the supplied cable) on the Interface to the screw terminals of the MultiMux in the following order:
Pin Color Connection Description
1
Brown 1H
Low side of CH1
2
Red 1L
High side of CH1
3
Orange 2H
Low side of CH2
4
Yellow 2L
High side of CH2
5
Green AG
Gage shield
6
Blue 12V
Power
7
Purple G
Ground
8
Grey EN
Enable
9
White CLK
Clock
10
Black Cable Shields
Cable Shield
The MultiSensor Interface does not support the 6-wire switching capability of the MultiMux so the 3H and
3L terminals are not connected.
TB ML MUX TB
Connection
Description Bendix Mux Cable
(5 pair)
Mux Cable
(6 pair)
1H 1H
High side of CH1 A White Brown
1L 1L
Low side of CH1 B Whites Black Browns Black
2H 2H
High side of CH2 C Red Red
2L 2L
Low side of CH2 D Reds Black Reds Black
3H NC
High side of CH3 White
3L NC
Low side of CH3 Whites Black
AG S
Gage shield E Blue & Blues Black Blue & Blues Black
12V 12V
Power F Yellow Yellow
G GND
Ground G Yellows Black Yellows Black
EN EN
Enable H Green Green
CLK CLK
Clock J Greens Black Greens Black
S
Cable Shield K Shield Wires from
White & Red Pair
plus Overall
Shield Wires from
Brown & Red Pair plus
Overall