User`s guide
Section 2
–
M
icro
Mux Operation and Installation
5
2.2 Datalogger Connections
The MicroMux is connected to the Controller or MultiLogger Mux Terminal Board (or ML MUX TB) using
the screw terminals. The common screw terminal block is located on the left side of the terminal strip
The table below lists the connections for the screw terminal block:
2.3 Instrument Connection
The way instruments are connected to the MicroMux will vary slightly depending on the Mode selection
(section 2.1).
The following table illustrates typical connection techniques for each of the operating modes.
Mode Description Example
4 Channel
(4-wire)
8 Channel
(2-wire)
2.4 MultiLogger Software Configuration
To configure MultiLogger to use the MicroMux select CAN
MicroMux as your multiplexer Model on the Configure |
Multiplexers form. Before the individual channels may be
edited you must select a Gage Type. Select either 4
Channels (default), 8 Channels to match the DIP switch
settings of the MicroMux.
If the VWDSP Interface is being used, be sure to select the
VWDSP Gage Type, as shown.
MicroMux
4 Channel
MicroMux
8 Channel
Description 10-Pin
Bendix
(16/32
board)
Mux Cable
(5 pair)
(4/8 board)
Mux Cable
(6 pair)
(48Ch board)
1H 1H High side of CH1 A White Brown
1L 1L Low side of CH1 B White’s Black Brown’s Black
2H Not Used High side of CH2 C Red Red
2L Not Used Low side of CH2 D Red’s Black Red’s Black
S S Cable Shield K Shield Wires from
White & Red Pair
plus Overall
Shield Wires from
Brown & Red Pair
plus Overall
12V 12V Power F Yellow Yellow
G GND Ground G Yellow’s Black Yellow’s Black
EN EN Enable H Green Green
CLK CLK Clock J Green’s Black Green’s Black
H1
L1
H2
L2
H1
L1
H2
INSTRUMENT #1
INSTRUMENT #2
L2
H1
L1
H2
L2
H1
L1
H2
INSTRUMENT #1
TEMPERATURE #1
L2