User manual
Chapter 4: Programming the TVS Phason
36
To program high and low temperature alarm settings
The examples in the following procedure use program A. Program A displays as a
pr, program B displays as bpr, program C displays as Cpr, and so on.
1. Press Program until the program you want to adjust displays, for
example Apr for program A.
2. Press Select.
The display shows Œ0, the first item in the Program settings
menu.
3. Press Down until the setting you want to adjust displays, for
example Œ11for the High temperature alarm, and then press
Select.
The display shows the current setting.
4. Press Up or Down to adjust the setting and then press Select.
The control returns to the Program settings menu.
5. Repeat steps 3 to 4 for each alarm setting you want to adjust.
6. To return to the Main menu, press Back once. To return to the Main display, press Back twice.
To enable or disable alarms
1. Press Program until ALen displays and then press Select.
The display shows 24, the first item in the Alarm enable menu.
2. To enable or disable the high temperature alarm, press Select.
The display shows the current configuration.
a) Press
Up or Down to toggle between no (not enabled) and yes
(enabled) and then press Select.
The control returns to the Alarm enable menu.
3. To enable or disable the low temperature alarm, press Up or Down
until25 displays and then press Select.
The display shows the current configuration.
a) Press
Up or Down to toggle between no and yes and then
press
Select.
The control returns to the Alarm enable menu.
4. To enable or disable the probe damage alarm, press Up or Down until
26 displays and then press
Select.
The display shows the current configuration.
a) Press Up or Down to toggle between no and yes and then press Select.
The control returns to the Alarm enable menu.
A
pr
Œ
22
*
9‡0
A
L
en
24
*
no