User manual
TVS user manual What you need to know before programming your TVS
31
Parameter Program A Parameter Program A
1
2
3
4
5
6
7
8
9
10
11
12
Group set point (°F)
Stage 1 idle speed (%)
Stage 1 idle range (°F)
Stage 1 set point (°F)
Stage 1 differential (°F)
Stage 2 idle speed (%)
Stage 2 idle range (°F)
Stage 2 set point (°F)
Stage 2 differential (°F)
Stage 3 set point (°F)
High temperature alarm
(°F)
Low temperature alarm (°F)
85.0
20
80.0
85.0
86.5
20
87.0
87.0
88.5
89.0
95.0
80.0
13 and 14 are not used in the example.
15
16
17
Stage 1 configuration
Stage 2 configuration
Stage 3 configuration
COOL
COOL
COOL
18 to 23 are not relevant in the example.
24
25
High temperature enable
Low temperature enable
YES
YES
0% 100% 0% 100%
86.5°
85.0°
80.0°
Fan speed
88.5°
87.0°
89.0°
95.0°
80.0°
Fan speed
3
4
5
2
8
9
1
6
20% 20%
7
10
15 16 17
11
12
25
24