Chapter 2: Installing your TVS Phason
20
A Slide three pieces of heat shrink tubing over the wires: one for the red wire, one for the black
wire, and one for both.
B Strip the ends of the wires and then twist them together.
C Solder the wires together using rosin-core flux solder. DO NOT use acid core solder.
D Slide the heat shrink tubing over the solder joints.
E Shrink the tubing using a heat gun.
F Your connection should look like this.
To use four-zone averaging
The TVS can monitor the temperature in four different zones using four-zone averaging. The
control takes an average of the temperatures measured by the four probes and then operates
according to the average temperature.
You must use
four probes for averaging. Using two, three, or more than four probes
measures the temperature incorrectly.