Programming instructions
Configuring Power Blocks
23
The Relay configuration window displays.
4. Select Curtain open.
The window updates and asks you to select the close relay.
If there is only one relay available, an Information window displays. Read the information and
then click OK. Follow the instructions from the window.
5. Beside Unused relays, select a relay to use for closing the curtain.
6. Beside Name, type a descriptive name for the curtain.
7. If you are using tunnel mode, select Closed during tunnel mode.
8. If the curtain needs to close when it is raining, select Closed when raining. This option is available
only if you have a Phason Rain Sensor connected.
9. Click OK to save the changes and return to the Power Block configuration window.
10. If required, repeat steps 3 to 9 for other relays you want to configure for curtain control.
11. Follow the instructions for configuring other relays or variable stages, or click Close to return to
the Configuration window
Enabling additional probes, deicing, and rain detection (on page 16)
Configuring variable stages (on page 18)
Configuring relays for actuators (on page 20)
Configuring relays for heating, cooling, and duty cycle (on page 24)
Configuring relays for timed events (on page 26)
Configuring relays for disconnecting DC variable stages (on page 28)