Installation Instructions
MODELS
MODELS
CP48HPWP,  CP56HPWP,
CP60HPWP, CP36, CP48, CP56BR, CP56F&R, 
CP56S, CP56C&P
READ AND SAVE THESE INSTRUCTIONS
Note to Installer: You are obligated to pass these instructions on to
building maintenance or location Supervisor.
AGRICULTURAL
&
INDUSTRIAL
CEILING FANS
M0090 - 03/16/11
•   I N S TA L L AT I O N   I N S T R U C T I O N S   •
•       W A R N I N G       •
1. Be  sure  to  shut  off  electrical  supply  at  circuit  breaker  before
installation.   This  installation  is  to  be  in  accordance with local  and
national electrical codes.
2. To  reduce  the  risk  of  personal  injury,  DO  NOT bend  the  blade
brackets  when installing or cleaning the fan.  Also, DO NOT insert
foreign objects in between rotating blades.
3. Any field alteration or changed downrods “WARRANTY VOIDS” any
hanging mechanism warranty or liability.
•       C A U T I O N       •
1. Installation work and electrical wiring must be done in accordance 
with NEC (NFPA 70) and all applicable local codes and standards 
including fire rated constructions and must be done by a 
qualified electrician.
2. Remove fan from the carton carefully and check for shipping 
damage.  Check blades for bends and dents. In case assistance 
is required please contact our service centre.
3. Check that the supply voltage corresponds to the rated voltage 
on motor of fan you have selected.
4. Do not install the fan close to the door entrance.  Ensure at least 
3 feet distance from end of the blades.
5. Ensure that you have a water proof model if installing in a 
wet/damp location.
6. Fan blades must be at a minimum of 10 feet from the floor when 
the fan is installed.
7. Make sure hanger hook is mounted securely to the structural 
ceiling.
8. Fan is suitable for operation on Solid State controls.
9. The fan shall not directly be supported by the outlet box.
10. All set screws must be checked and re-tightened where necessary 
after installation. No lubricants should be used on screws or 
hooks.
11. To reduce the risk of personal injury install the safety cable 
(per Fig. 1).
12. DO NOT attach blades before hanging the fan.
•       H A N G I N G   &   A S S E M B L Y       •
1. Using Machine Threaded Hooks for Steel Frame Ceiling (Fig. 1)
- Put the threaded J-Hook through junction box, winding nut to 
bottom of thread.
- Insert the hook with the box through slit in bottom of open web
steel joists.
- Put large washer, lock washer and nut on the hook loosely.
- Secure spark plate onto junction box.  Feed power wires through
spark plate for ease of wiring.  (Spark plate is not needed for fan
with a cord and plug.)
- Hang the fan on the J-hook.
- Tighten the top lock washer and nut until secure.
- Install the Eye Bolt onto the steel frame ceiling beside the junction
box.
2. Insert  the  safety  cable  into  the  Eye  Bolt  through the  slit  and  then
close the Eye Bolt loop. NOTE: Knot in safety cable is there for
extra strength. DO NOT UNDO KNOT.
3. Connect the lead wires to the power supply, (shown in Fig. 3).  
FOR CORD & PLUG FANS:
Simply insert the plug into the receptacle at the ceiling.  
FOR FORWARD/REVERSE MODELS:
Downdraft Direction:
Connect blue and black wires of fan to “hot” wire, red and white wires
to neutral wire and green wire to ground wire.
Updraft Direction:
Connect red and black wires of fan to “hot” wire, blue and white wires
to neutral wire and green wire to ground wire.
NOTE:    Wiring  connections  should  be  turned  upward  and
pushed carefully up into the outlet box.
4. Slide up the upper canopy and affix it with the set screws. Leave a
minimum of 1/8” between ceiling and canopy.
5. Mount the fan blades onto the motor head with screws and spring
washers (see Fig. 2 for details).
NOTE: If  wiring  for  updraft  only:  blades  can  be  reversed  for
increased fan performance.
6. Tighten set screws on upper and lower canopies.
Page 1 of 3