Installation Instructions

BLUEBLUE
BLACKBLACK
WHITEWHITE
REDRED
WHITEWHITE
BLACKBLACK
120 VOLTS SUPPLY120 VOLTS SUPPLY
GREENGREEN
MOTORMOTOR
Reference Numbers:
1. Upper Canopy 11. Steel Frame Ceiling
2. Set Screw 12. J-Hook Nut
3. Blade Mounting Screw 13. Spring Washer
4. Blade Bracket 14. Washer
5. Fan Blade 15. Threaded J-Hook
6. Vibration Absorber 16. Safety Cable
7. Spark Plate (NA for Cord & Plug) 17. Lead Wires (or Cord & Plug)
8. Lower Canopy 18. Downrod
9. Blade Mounting Spring Washer 19. Eye Bolt
10. Motor Head 20. Junction Box (Not provided)
Figure 1
Figure 2
REDRED
BLUEBLUE
WHITEWHITE
BLACKBLACK
120 VOLTS SUPPLY120 VOLTS SUPPLY
BLACKBLACK
WHITEWHITE
GREENGREEN
22
11
55
4466
33
MOTORMOTOR
MOTORMOTOR
REDRED
WHITEWHITE
BLACKBLACK
BLUEBLUE
REDRED
BLUEBLUE
YELLOWYELLOW
WHITEWHITE
BLACKBLACK
W
HITEWHITE
120 VOLTS SUPPLY120 VOLTS SUPPLY
CNFRMC5CNFRMC5
GREENGREEN
Both Updraft & Downdraft
Using Canarm CNFRMC5 Control
M
ODELS: CP36, CP48, CP56S, CP56BR, CP56F/R
HIGH PERFORMANCE MODELS: CP48, 56, 60 HPWP
BLACKBLACK
WHITEWHITE
REDRED
BLUEBLUE
WHITEWHITE
BLACKBLACK
120 VOLTS SUPPLY120 VOLTS SUPPLY
GREENGREEN
MOTORMOTOR
MODELS: CP36, CP48, CP56S, CP56BR, CP56F/R
HIGH PERFORMANCE MODELS: CP48, 56, 60 HPWP
Figure 3
T R O U B L E S H O O T I N G
Trouble: Suggestion:
1. Fan will not start. - Check fuses and circuit breakers
- Check wiring connections to fan.
- Check wiring connections in lower canopy.
Caution: Turn power off for last two items.
2. Fan sounds noisy. - Check to make sure all screws in
motor are snug.
- Check to make sure that all blade
bracket screws are tight.
- Some motors are sensitive to signals
from solid state variable controls. If this
type of control is used some electrical
noise from the motor is normal and will
not affect performance.
For quiet operation use Canarm’s
models CQ004 “Church Quiet” controls.
- Allow a 24 hour break in period to
eliminate most noises.
3. Fan wobbles. - Check that all blades are screwed firmly
to motor.
- Check distance from tip of blades to
ceiling, gently bend up or down until all
distances are the same.
- Make sure upper canopy is 1/8” from
ceiling.
- Make sure that hanging hooks are
secured tightly to ceiling.
Page 2 of 3
Dow
nd
ra
ft
MODELS: CP36, CP48, CP56S, CP56BR, CP56F/R
HIGH PERFORMANCE MODELS: CP48, 56, 60 HPWP
Updraft
MODELS: CP36, CP48, CP56S, CP56BR, CP56F/R
HIGH PERFORMANCE MODELS: CP48, 56, 60 HPWP
Both Updraft & Downdraft
Using Canarm MC Series Control and DPDT Switch
Note: On the Double Pole, Double Throw Switch,
Jumper Pin 1 to 4, 3 to 6
1
4
3
6
2
5
POTENTIOMETER
CNFRMC5
CONTROL
DPDT SWITCH
MC SERIES
CONTROL
(if applicable)
MC SERIES
CONTROL
(if applicable)