Product Manual

TUBEAXIAL-M
4
Start Up
Restore power to the fan, turn it on and check for the following.
Correct rotation
Improper amperage
Excess vibration
Unusual noise
Incorrect belt tension or alignment
If a problem is discovered shut off the fan and refer to the section on troubleshooting to
discover the cause of the problem. The fan should be inspected after 30 minutes, 8 hours and 24
hours of operation to ensure all fasteners are tight and belts are properly tensioned and aligned.
MAINTENANCE
WARNING
________________________________________________________________________
Disconnect and secure to the OFF position all electrical power to the fan prior to inspection or
servicing. Failure to comply with this safety precaution could result in serious injury or death.
.
1. Fans should be checked at least once a year. For critical or severe applications, a routine
check every two or three months is suggested.
2. When removing or installing a belt, do not force the belt over the sheave; loosen the
motor mount so that the belt can be easily slipped over the sheave.
3. The belt on belt driven units should be removed and carefully checked for cracks, ply
separation and irregular wear. A small irregularity in the contact surface of the belt will
result in noisy operation. If any of these defects are apparent, the belt should be replaced.
At the same time, check the sheaves for chips, dents or rough surfaces that could damage
the belt.
4. The correct belt tension is important. Too tight a belt will result in excess bearing
pressure, which can cause premature bearing failure and may cause the motor to
overload; too loose a belt will result in slippage, which will burn out belts. Proper belt
deflection should be 1/64” (half way between sheave centers) for each inch of belt span
when a force of approximately five lbs. is applied.
5. The belt alignment should be checked to be sure that the belt is running perpendicular to
the rotating shaft. The motor and drive shafts must be parallel.
6. A periodic inspection of all fasteners should be carried out to ensure they have not
loosened due to vibration. Particular attention should be paid to fasteners
attaching the wheel to the shaft and those attaching the shaft to the bearings.