Operation and Maintenance Manual
CANAM TECHNOLOGY, INC. (CTI)
MARK-IVD 800MHZ NARROWBAND SIGNAL BOOSTER M4DBDA8 O&M MANUAL
Page 34 of 46
Rev1 May/2015
Reflected Power
(dBm)
Composite Reflected Power.
The Status will be “Undetermined” when the power
is not readable; “Normal” when it is below the
threshold; “Triggered” if it is above the threshold
and “Latched” when a previous Reflected Power
Alarm has not been cleared.
Current Drain Idc (A)
MCPA DC current drain.
The Status indicator will be green when the current
is within the operating levels, red otherwise.
Temperature (ºC)
MCPA heat-sink temperature.
The Status indicator will be green when the
temperature is within the operating levels, red
otherwise.
Analog Interface Meters and Status
Modules Summary
Indicator is Green if module is active with no alarms,
red otherwise.
Comm Status
Indicator is Green if Analog Interface Card
communication is working, red otherwise.
RF Output (dBm)
Composite Output Power. This is the multi-carriers
signal coming out of the DSP filtering process, used to
drive the broadband output MCPA.
The Status indicator will be green if the power is
above the threshold, gray otherwise (no traffic).
Current Drain Idc
(mA)
Analog-Module DC Current Drain (mA).
The Status indicator will be green when the current is
above the threshold, red otherwise.
Local Oscillator
Indicator is Green if Local Oscillator is locked, red
otherwise.