This page shows meters and the different alarms and meters. The auto-refresh
radio-button allows periodic page updates every 5 seconds approximately.
Summary Alarm
Master Summary alarm Indicator. Green if no single
alarm is present in the system, red otherwise.
Major Alarm
Major Alarm indicator. It summarizes the DSP Modules
Status alarms, the RF Output Status alarm and the off-
air Receive Warning alarm. The indicator is Green if all
this alarms are ok, red otherwise.
Minor Alarm
Minor Alarm indicator. It summarizes the alarms that
concern to the Fan status, current consumption and
temperature status. The indicator is Green if all this
alarms are ok, red otherwise.
SNMP Agent
Shows the SNMP Agent current status.
MCPA’s Meters and Status
Amplifier Status
Indicates if the MCPA Output is “Unmuted”,
“Muted” or “Muted by Alarm”(in case the MCPA
Reflected Power Alarm is “Triggered” or
“Latched” and the option “Enable Automatic
Mute upon Reflected Power Alarm” has been
selected in Main Settings page).
Output Power (dBm)
Composite Output Power.
The Status will be “Undetermined” when the power
is not readable; “Normal” when it is above the
threshold and “Triggered” if it is below the
threshold.