Operation and Maintenance Manual
CANAM TECHNOLOGY, INC. (CTI)
MARK-IVD 800MHZ NARROWBAND SIGNAL BOOSTER M4DBDA8 O&M MANUAL
Page 20 of 46
Rev1 May/2015
Table 3 – Alarm available at the Front Panel LCD
Parameter
Possible values
Remarks
Summary Alarm
OK /BAD
Master Summary Alarm
DSP Conf Stat
OK /BAD
Status DSP Configuration
UL FWD Alarm
“N/A”/OK/BAD
UL MCPA Forward Power Alarm
DL FWD Alarm
“N/A”/OK/BAD
DL MCPA Forward Power Alarm
UL REF Alarm
LAT/“N/A”/OK/BAD
UL MCPA Reflected Power Alarm
DL REF Alarm
LAT/“N/A”/OK/BAD
DL MCPA Reflected Power Alarm
I PA UL
OK /BAD
UL MCPA DC current within expected range
I PA DL
OK /BAD
DL MCPA DC current within expected range
I PSU 5V
OK /BAD
PSU 5V DC current within expected range
I PSU 12V
OK /BAD
PSU 12V DC current within expected range
UL TEMPERATURE
OK /BAD
UL MCPA temperature within expected range
DL TEMPERATURE
OK /BAD
DL MCPA temperature within expected range
AIC UL IDC
OK /BAD
UL AIC current is lower than expected threshold.
AIC DL IDC
OK /BAD
DL IAC current is lower than expected threshold.
AIC UL Status
OK /BAD
UL Analog Interface Module Status
AIC DL Status
OK /BAD
DL Analog Interface Module Status
AIC UL Comm
OK /BAD
UL Analog Interface Module Communication
AIC DL Comm
OK /BAD
DL Analog Interface Module Communication
Local Osc UL
OK /BAD
UL Local Oscillator Status
Local Osc DL
OK /BAD
DL Local Oscillator Status
SubSystem UL
OK /BAD
UL SubSystem Status
SubSystem DL
OK /BAD
DL SubSystem Status
IALC ATT UL
OK /BAD
UL Analog Interface Module Attenuation Status
IALC ATT DL
OK /BAD
DL Analog Interface Module Attenuation Status
AIC Temp UL
N/A
UL Analog Interface Module Temperature
AIC Temp DL
N/A
DL Analog Interface Module Temperature
Intake Fan 1
OK / BAD
Front Panel Fan summary alarm
Exhaust Fan 1
OK / BAD
Rear Panel Fan summary alarm
Intake Fan 2
OK / BAD
Front Panel Fan summary alarm
Exhaust Fan 2
OK / BAD
Rear Panel Fan summary alarm
DSP FAN
OK / BAD
DSP Module Fan alarm