Operation and Maintenance Manual
CANAM TECHNOLOGY, INC. (CTI)
MARK-IV VHF BROADBAND SIGNAL BOOSTER M4BBDAV O&M MANUAL
Page 37 of 39
Rev0 April/2015
b. On the other hand, if the user chooses software control, the controller
will respond to these software commands instead of to the opto-isolated
inputs.
Also, there are four M4-BBDA settings that can be controlled using software
commands:
Output MCPA ALC Limit
Level
Output limiter set point 30 to 37 dBm.
Output MCPA ALC Enable
Check-box to enable/disable the output ALC.
Enable Automatic Mute
upon Reflected Power
Alarm
Check-box to enable/disable automatic
MCPA mute upon excessive reflected power.
Enable Reflected Power
Alarm Status Latch
Check-box to enable/disable the alarm status
latch.
F.2.2.3 Updating operational settings
Using the checkboxes click to check/un-check.
Press enter or “Apply” button for the system to validate the data and
apply changes.
o If the value is not valid, an error message will be displayed (see
Figure 11) and the new value will be not accepted keeping the
previous value.
The current state applied to system is saved to the controller’s internal
nonvolatile memory for effective recovery after a power loss or system
reset.