Datasheet

Camtec Power Supplies GmbH – Gewerbestrasse 30 – D-76327 Pfinztal – Germany
p.4/8 (12.2017.02.0)
Phone +49(721)46596-0 - Fax +49(721)46596-77 – www.camtec-gmbh.com - info@camtec-gmbh.com
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Manual und Technical Details
Programming Time Vout [ms]
Model
HSEUREG072
01
.018
.030
.060
.090
.1
3
0
.
18
0
Rise Time 0
-
100%, 10/100% Last, [ms] typ.
15/15
15/15
15/15
15/15
15/15
15/15
Slew Rate 90
-
10%, 10/100% Last, [ms] typ.
19/1.9
62/6.2
30/3.0
34/3.4
31/3.1
60/6.0
Output Capacity, [mF] typ.
8.56
8.56
1.52
0.54
0.23
0.23
Interface Latency
15ms including signal latency for 0
-
Umax programming
Analog
Interface
Pin
Name
Type
Function
Signal
Remarks
1
Ureg +
Input
Voltage Programming
0
-
10Vdc/20mA & 0
-
20mA
multi-functional interface
500 Ω working resistance with
voltage
programming
2
Ureg
-
Input
3
Sense +
Input
Sense Control
none
Compensation max. 2V per load line
4
Sense
-
Input
5
Remote +
Output
External Shutdown Remote
ON/OFF
Open Collector or Switch
Voltage drop <1V
with
typical
2.3mA
6
Remote
-
Output
Programming Interface
Ureg
The standard programming of the HSEUREG Series is an analog interface.
The output voltage is linearly proportional to the adjusted analog control
signal. If the control signal 0V applies the power supply delivers 0V at the
output. The power supply is already working from 0V output voltage and low
load with high precision.
The analog inputs are non-floating. The mass is connected to the DC
negative output.The burden of the interface is 500Ω. The latency to full
compensation of V/C on the interface from 0-100% is 15ms for all
HSEUREG models.
C
O
N
V
E
R
T
E
R
F
I
L
T
E
R
P
I
D
C
O
N
T
R
O
L
C
T
1 = transient filter
2 = rectifier
3 = inrush limiter NTC
4 = load capacitor
5 = transformer
6 = storage choke