Datasheet
Camtec Power Supplies GmbH – Gewerbestrasse 30 – D-76327 Pfinztal – Germany
p.7/8 (12.2017.02.0)
Phone +49(721)46596-0 - Fax +49(721)46596-77 – www.camtec-gmbh.com - info@camtec-gmbh.com
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Electrical Safety (Factory
-
Test / Fieldtest Owner)
T
A
B
C
¹)
D
Type Test
60s
2500Vac
3000Vac
500Vdc 3000Vac
Factory Test
5s 2000Vac
2000Vac
500Vdc 1000Vdc
Field Test
2s 2000Vac
2000Vac
500Vdc 1000Vdc
¹)
≥60Vdc= 2400Vdc
Type and factory-test are reserved to the manufacturer. While repating damage can
happen to the power supply unit. For the field-test (owner-test) follow the below instruction:
a) Use suitable test equipment, raising the voltage slowly
b) Short circuit L1 and N, and all the DC output terminals.
c) Use only test voltages of 50/60Hz. The outputs are unearthed and
therefore they have no resistance to GND/PE.
d) If the residual voltage is ≥60Vdc, observe the safety standards.
Use only specially insulated screwdriver to trim the Ua/Ia.
Terminal Connects:
AC Main Input
GND common
N - wire
L -
wire
DC Mains Outputs
DC + voltage
DC + voltage
DC - voltage
DC - voltage
Inputs/Outputs
Ureg = programmable voltage input
Ureg = programmable current input
SD = shut down input
Sense = Sensing (compensation: 2V)
Mechanics & Installation
Instruction
of the HSEUreg
Stable metal/aluminium housing IP20. To allow adequate convection, a free air space of 50mm (top/bottom) and 10mm (sidewalls) is
required; and for active devices 15mm space from the sidewalls. For proper air convection it is necessary to install the HSEUreg.
One can use the DIN-Rail installation (equiped standard) with our patented 35mm DIN-Rail bracket according to EN60275. It is easy to
mount/dismount while snaping it onto the 35mm DIN-Rail - no tools necessary.
It is not allowed to install the HSEUREG in other mounting direction then below drawings.
Device
Top
Device
Bottom
natural convection
>20 CFM
Mounting Instruction
Bottom
forced convection:
Top
Device
Bottom
Rail