CAMPLUX 20L Residential Indoor Tankless Gas Water Heater USE & CARE MANUAL 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com (844) 538-7475 support@camplux.
www.camplux.com 1 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances. • WHAT TO DO IF YOU SMELL GAS - Do not try to light any appliances. - Do not touch any electrical switch; do not use any phone in your building. - Immediately call your gas supplier from a neighbor’s phone.
www.camplux.com YOU'RE ALL SET! 2 Thanks for purchasing your new Camplux 20L residential tankless water heater. This convenient, safe and high efficiency product will open the doors to enjoying endless hot water. We highly suggest you take the time to read through all of the safety and installation procedures in this manual, before attempting to install your new residential water heater. Always remember we're here for you via our online helpdesk located at www.camplux.
www.camplux.com 3 It is imperative that all persons who are expected to install, operate or adjust this water heater read the instructions carefully so they may understand how to perform these operations. If you don’t understand these instructions or any terms within it, seek professional advice. Any questions regarding the operation, maintenance, service or warranty of this water heater should be directed to the seller from whom it was purchased.
www.camplux.com Warning & You’re All Set......................................................................................................................................................................................... 1-2 Safety Information...................................................................................................................................................................................................... 2-8 Installing The Water Heater.............................
www.camplux.com 5 WARNING Gasoline, as well as other flammable materials and liquids (adhesives, solvents, paint thinners etc.), and the vapors they produce are extremely dangerous. DO NOT handle, use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity of a water heater or any other appliance. Be sure to read and follow the labels on the water heater, as well as the warnings printed in this manual.
www.camplux.com 6 DANGER WATER TEMPERATURE SETTING Safety and energy conservation are factors to be considered when selecting the water temperature setting. Water temperatures above 125°F can cause severe burns or death from scalding. The thermostat is adjusted to its lowest temperature position when shipped from the factory. Be sure to read and follow the warnings outlined on the label pictured below.
www.camplux.com 7 DANGER NATURAL GAS AND LIQUEFIED PETROLEUM MODELS Both propane and natural gas have odorants added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorants. If you are unsure or unfamiliar with the smell of propane or natural gas, ask the gas supplier. Other conditions, such as “odorants fade”, which causes the odorant to diminish in intensity, can also hide or camouflage a gas leak.
www.camplux.com 8 FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that residential water heaters must be braced, anchored or strapped to resist falling or horizontal displacement due to earthquake motions. For residential water heaters up to 52 gallon capacity, a brochure with generic earthquake bracing instructions can be obtained from: Office of the State Architect, 400 P Street, Sacramento, CA 95814 or you may call 916-445-8100 or ask a water heater dealer.
www.camplux.com 9 INSTALLING THE WATER HEATER Indoor Location Proper operation of the water heater requires air for combustion and ventilation. Provisionsfor combustion and ventilation air must comply with referenced codes and standards. • Installation distances may vary by local code. It is the installer’s responsibility to verify installation requirements. • Make sure before installation that the gas type you will use is the same type on the data plate.
www.camplux.com WARNING: Combustible construction refers to adjacent walls and ceilings and should not be confused with combustible or flammable products and materials. Combustible and or flammable products and materials should never be stored in the vicinity of this or any gas appliance. Combustion and Ventilation Air A confined space is one having a volume of less than 50 cubic feet per 1,000 BTU/Hr of the aggregate input of all appliances within that space.
www.camplux.com 11 Check the Unit Inspect the water heater for possible damage. Check the markings on the rating plate of the water heater to be certain the type of gas supplied corresponds to the water heater requirements. Verify all included parts are present (see below).
www.camplux.com WATER SUPPLY CONNECTIONS Plumbing should be carried out by a qualified plumber in accordance with local codes. Use approveplumbing materials and tools only. Install a check valve between the water heater and the water shutoff valve. (See illustration below). To conserve energy and to prevent freezing, insulate both cold and hot water supply lines. DO NOT cover the drain valves. Install a shutoff valve near the inlet of the water heater for service and draining purposes.
www.camplux.com 13 IMPORTANT: Do not apply heat to the HOT or COLD water connections. Any heat applied to the water supply fittings will permanently damage the internal components of the water heater. NOTICE: If the water flow resistance of a shower head is too high, the burner in the water heater will fail to ignite. Keep the shower head clean from debris that could cause additional pressure drop.
www.camplux.com 14 GAS SUPPLY WARNING: Do not attempt to convert this water heater for use with a different type of gas other than the type shown on the rating plate. Such conversion could result in hazardous operating conditions. Please have a professional connect the gas pipe. The supplied Manual Gas Appliance Shut Off Valve must be installed at the gas connection of the water heater at the time of installation.
www.camplux.com 15 RELIEF VALVE A new pressure relief valve, complying with the Standard for relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, must be installed at the hot water outlet connection of the water heater at the time of installation. Local codes shall govern the installation of relief valves.
www.camplux.com 16 Leak Testing WARNING: Never use an open flame to test for gas leaks, as property damage, personal injury, or death could result. The water heater and its gas connections must be leak tested at normal operating pressures before it is placed in operation. • Turn on the gas shut-off valve(s) to the water heater. • Use a commercial leak detector or soapy water solution to test for leaks at all connections and fittings. Bubbles indicate a gas leak that must be corrected.
www.camplux.com 17 Use a vent pipe with an antidisconnection structure. The use of a High Temperature Silicone (500°F) may be required to seal vent connections. To prevent accidental gas exhaust leakage, apply a 1/4” wide bead approximately 1/4” from the end and another bead against the joint side of the stop bead. Follow vent manufacturer’s installation instructions. The unit can be vented either horizontally or vertically.
www.camplux.com VENTING LENGTHS 18 Maximum Vent Length Owner must refer to vent manufacturer’s instructions and specifications. The system will not operate if there is excessive restriction (pressure drop) in the venting system. A maximum of 32 feet of vent pipe may be used provided there is only one 90° elbow in the system. If additional elbows are required: two elbows can be used with 27 feet, and three elbows can be used with 22 feet of vent pipe. A 90° elbow is equivalent to 5 feet of straight pipe.
www.camplux.com VENT TERMINATION CLEARANCES DRAWING 19 For Non-Direct Vent Installations In The US And Canada A= B= US Installation 1 Clearance above grade,veranda, porch,deck,or balcony Clearance to window or door that may be opened Canadian Installation 2 12 in (30 cm) 12 in (30 cm) 4ft (1.
www.camplux.com For clearances not specified in ANSI Z223.1/NFPA 54 or CSA-B149.1, one of the following shall be indicated: A) A minimum clearance value determined by testing in accordance with Clause 5.20 or; B) A reference to the following footnote: Clearance in accordance with local installation codes and the requirements of the gas supplier. • A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
www.camplux.com 21 Inner Thimble Section Outer Thimble Section Side View WARNING: Use UL approved Category III vent material only. Other vent material is permitted. Owner must refer to vent manufacturer’s instructions and specifications. Please visit a local hardware store or online marketplaces to purchase Φ3” Category III Stainless Steel Venting for certified installation.
www.camplux.com (OPTIONAL) REMOTE CONTROL CONNECTION, INSTALLATION AND SET 22 (For Panel Control / Remote Control & Remote Control Units) Panel Control/Remote Control and Remote Control units will work with either one or two remote controls. If two remotes are desired, a wire connector will need to be provided. To connect the remote control. 1. For one control: Plug the aviation joint into the socket directly on the water heater (see illustration below) Remote Control Aviation Joint 2.
www.camplux.com 23 Base of Control Wall Rubber Screw Wood Thread Screw 3. Replace the front cover on the remote control. WARNING: Field wiring connections and electri cal grounding must comply with local codes, or in the absence of local codes, with the la test edition of the National Electrical Code,ANSI/NFPA 70, or in Canada, Canadi an Electrical Code, CSA C22.1Part1. ELECTRICAL CONNECTION POWER CORD • The electric power supply requirement for this water heater is 120 VAC/60HZ, 2 Amps.
www.camplux.com HARDWIRING THE ELECTRICAL 24 CONNECTIONS • Wiring should be carried out by a qualified electrician in accordance with local codes. • The water heater requires 120 VAC/60Hz and should be properly grounded. • DO NOT connect grounding wire to water pipes, gas pipes, telephone cables, lightning conductor circuits and to grounding circuit of other equipment that carry a ground-fault interrupter. • An ON/OFF switch must be provided and installed for the incoming 120VAC power.
www.camplux.com 25 INSULATION BLANKETS WARNING: If local codes require external application of insulation blanket kits the manufacturer’s instructions included with the kit must be carefully followed. Insulation blankets, available to the general public, for external use on gas water heaters are not necessary. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. This water heater does not store water making an insulation blanket unnecessary.
www.camplux.com 26 NOTICE: The hot and cold pipes should be insulated as shown help to provide additional freeze protection. DURING INSTALLATION OF THIS WATER HEATER MUST DO • DO check inlet gas pressure to ensure that it is within the range specified on the rating plate. • DO provide adequate air for combustion and ventilation as discussed in the Use & Care Manual and the National Gas Code (CAN/CGA B 149 in Canada). • DO maintain proper clearances to combustibles as specified by applicable code.
www.camplux.com 27 MOUNTING THE WATER HEATER Make sure the location of the water heater allows for easy access and operation. In case of dry wall or concrete wall use dry wall anchors or lag bolts. The water heater requires 120VAC/ 60Hz. Have a receptacle with ground terminal near the water heater. The length of the powersupply cord is 5 feet. Drill the holes as per the sizes in the figure to the left, put 2 expansion screws into the top holes, and 2 rubber screws into the bottom holes.
www.camplux.com 28 Installation Check List A. Water Heater Location • Installed indoors. • Close to area of mostly used outlet. • Protected from freezing temperatures. • Proper clearance from combustible surfaces observed. • Sufficient fresh air supply for proper operation of water heater. • Air supply free of corrosive elements and flammable vapors. • Provisions made to protect area from water damage. • Sufficient room to service heater.
www.camplux.com 29 FOR YOUR SAFETY BEFORE USING THE WATER HEATER explosion may result causing property damage, personal injury or loss of life. A. This water heater does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. B. BEFORE OPERATING smell all around the water heater area for gas. Be sure to smell next to the a commercial leak detector or soapy water.
www.camplux.com OPERATING THE WATER HEATER Turning on the Water Heater 1. Make sure the gas type you will use is same as the type on the data plate. 2. Turn on the main gas valve, plug in the power cord (be sure the socket is well grounded), and press the “ON/OFF”button on the control panel. Set temperature to 120° F. 3. Turn on the faucet, and the fan will start working. You will hear the ignition sound after a few seconds. The burner will ignite, and hot water will come out.
www.camplux.com 31 Output temperature of water is regulated by setting the temperature on the front of the remote control. Safety factors should be considered when selecting the water temperature setting of the water heater’s remote control. The remote control was set at 110°F before the water heater was shipped from the factory. This is the recommended starting point. Water temperatures above 120°F can cause severe burns or death from scalding.
www.camplux.com Water Quality Proper maintenance of the water heater is required to ensure that your water meets EPA quality standards. • The following table shows the maximum contaminant levels allowed, based on the EPA National Secondary Drinking Water Regulations (40 CFR Part 143.3). NOTICE: If you suspect that your water is contaminated in any way, discontinue use of the water heater and contact an authorized technician or licensed professional.
www.camplux.com 33 Inspect the area around the water heater to ensure a safe operating environment. Keep water heater area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. Ensure the unit has not been damaged. If damage or denting is present, contact a service personnel to verify proper operation. Check for any abnormal sounds during normal operation of the water heater. All piping should be checked for gas and/or water leaks.
www.camplux.com Vacuum around the water heater for dust, dirt and lint on a regular basis. Clean the water heater and remote control by using a damp soft cloth with a few drops of mild detergent and gently wiping the surfaces of the unit. Wipe any remaining moisture with a dry soft cloth. To ensure sufficient ventilation and combustion air supply, proper clearances must be maintained. The water filters should be cleaned on a monthly basis. Combustion system is fan-assisted.
www.camplux.com DRAINING PROCEDURE 35 When the temperature falls below 32°F, water in your plumbing system or water heater can turn to ice and then expand causing damage to the water heater. This damage is not covered under the manufacturer’s warranty. If these conditions are anticipated, please drain the water heater as follows to help but not guarantee from freezing: 1. Shut off the main gas valve and power. 2. Shut off the inlet water valve. 3. Open all faucets. 4.
www.camplux.com 8. Remount the water filter. Close the hot water outlet drain valve. 9. Open the water shut-off valve and close again after making sure that water comes out from hot water faucets. (This step is to remove air from the water lines.) 10. Reconnect the breaker and turn the on/off switch to the ON position, fully open the gas shut-off valve and the water shut-off valve. NOTICE: The water heater may not operate unless the above procedure is followed correctly.
www.camplux.com 37 ERROR CODE GUIDE When an error code is displayed: • Close the hot water faucet, turn off the switch on the remote control. • Wait for about 5 minutes before turning the switch on again. • Open the hot water faucet. NOTICE: If an error code other than those listed below is displayed, immediately turn off the hot water faucet, take note of the error code, turn off the switch on the remote control and call the customer assistance number.
www.camplux.com REPLACEMENT PARTS 38 For models using natural or propane gas. WARNING: For your safety, DO NOT attempt to disassemble this unit for any reason. 20.Exhaust Outlet 19.Exhaust Collector 18.Anti-Freezer Thermostat 1.Heat Exchanger 17.Thermostat 16.Anti-Freezer 2.Ignition Needle 15.Heat Exchanger Protection Device 2.Ignition Needle 14.Burner Assembly 3.Flame Sensor Needle 13.Fan Assembly 4.Gas Distribution Pipe 12.PCB Board 11.Hot Water Temp. Sensor 5.Gas Valve Assembly 6.
www.camplux.com 39 IN THE BOX Item Description A Residential Tankless Gas Water Heater B Vent Pipe (Φ3.0”) Identification Quantity 1 piece NOT INCLUDED N/A C Pressure Relief Valve N/A D Fixing Kits 1 set E Manual 1 piece NOTE: Vent Pipe was not included from the original package. Please visit a local hardware store or online marketplaces to purchase Φ3” Category III Stainless Steel Venting for certified installation.
www.camplux.com CAMPLUX, ENJOY OUTDOOR LIFE! LIMITED WARRANTY INFORMATION Camplux hereby warrants this product to be free of material defects in materials and workmanship when installed and operated according to Camplux’s installation and operating instructions. This Limited Warranty extends to the original purchaser and subsequent owners, but only while the product remains as the site of the original installation. This Limited Warranty terminates if moved or reinstalled at a new location.
www.camplux.com 41 OUR OTHER RESIDENTIAL MODELS WA686 CA318 CM264 CM264 CA318 WA686 Use For INDOORS ONLY INDOORS ONLY OUTDOORS ONLY BTU 68,000 82,000 180,000 Flow Rate Rated 2.64 GPM Rated 3.18 GPM Rated 6.86 GPM Portable No No No Power Source 120 volts 120 volts 120 volts Gas Type Liquid Propane &Natural Gas Liquid Propane &Natural Gas Liquid Propane &Natural Gas Water Pressure 3.6-150 PSI 3.6-150 PSI 3.
3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com (844) 538-7475 support@camplux.
CAMPLUX 20L Chauffe-eau Au Gaz Résidentiel Sans Réservoir MANUEL D'UTILISATION ET D'ENTRETIEN 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com (844) 538-7475 support@camplux.
www.camplux.com 1 AVERTISSEMENT: Si les informations contenues dans ces instructions ne sont pas respectées mot par mot, un incendie ou une explosion pourrait en résulter, causant des dégâts matériels, des blessures physiques ou même la mort. • Ne stockez pas et n'utilisez pas d'essence ou d'autres liquides ou vapeurs inflammables à proximité de cet appareil ou de tout autre appareil. • QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ - Essayez de n’allumer aucun appareil.
www.camplux.com VOUS ÊTES TOUS PRÊTS! 2 Merci d’avoir acheté votre nouveau chauffe-eau résidentiel sans réservoir Camplux 20L. Ce produit pratique, sûr et à haute efficacité vous permettra pour profiter d’une eau chaude sans fin. Nous vous suggérons fortement de prendre le temps de lire toutes les instructions de sécurité et d'installation de ce manuel avant d’essayer d'installer votre nouveau chauffe-eau résidentiel.
www.camplux.com 3 Il est impératif que toutes les personnes qui sont censées installer, utiliser ou régler ce chauffe-eau lisent attentivement les instructions pour pouvoir comprendre comment effectuer ces opérations. Si vous ne comprenez pas ces instructions ou les termes qu’elles contiennent, demandez un conseil à un professionnel. Toute question concernant le fonctionnement, l’entretien, le service ou la garantie de ce chauffe-eau doit être adressée au vendeur chez qui vous l’avez acheté.
www.camplux.com Avertissement Et Tout Est Prêt ................................................................................................................................................................................ 1-2 Consignes De Sécurité ................................................................................................................................................................................................ 2-8 Installation Du Chauffe-eau ....................................
www.camplux.com 5 AVERTISSEMENT L'essence, ainsi que d'autres matériaux et liquides inflammables (adhésifs, solvants, diluants pour peinture, etc.) et les vapeurs qu'ils produisent sont extrêmement dangereux. NE PAS manipuler, utiliser ou entreposer de l'essence ou d'autres matériaux inflammables ou combustibles à proximité d'un chauffe-eau ou de tout autre appareil. Assurez-vous de lire et de suivre les étiquettes sur le chauffe-eau, ainsi que les avertissements imprimés dans ce manuel.
www.camplux.com 6 DANGER RÉGLAGE DE LA TEMPÉRATURE D'EAU La sécurité et la conservation de l’énergie sont des facteurs à prendre en compte lors du choix de réglage de la température d’eau. Des températures d'eau supérieures à 125 ° F peuvent causer des brûlures graves, voire mortelles. Le thermomètre est réglé sur sa position de température la plus basse lors de son expédition de l'usine. Assurez-vous de lire et de suivre les avertissements décrits sur l'étiquette illustrée ci-dessous.
www.camplux.com 7 DANGER MODÈLES À GAZ NATUREL ET AU PÉTROLE LIQUÉFIÉ Le propane et le gaz naturel contiennent des substances odorantes qui facilitent la détection des fuites de gaz. Certaines personnes peuvent ne pas être physiquement capables de sentir ou de reconnaître ces odeurs. Si vous n'êtes pas sûr ou si vous ne connaissez pas les odeurs du propane ou du gaz naturel, adressez-vous au fournisseur de gaz.
www.camplux.com 8 POUR INSTALLATIONS DANS L'ÉTAT DE LA CALIFORNIE La loi californienne stipule que les chauffe-eau résidentiels doivent être contreventés, ancrés ou attachés pour résister aux chutes ou aux déplacements horizontaux dus aux mouvements des tremblements de terre.
www.camplux.com 9 INSTALLATION DU CHAUFFE-EAU Emplacement Intérieur Le bon fonctionnement du chauffe-eau nécessite de l'air pour la combustion et la ventilation. Les dispositions relatives à l'air de combustion et de ventilation doivent être conformes aux codes et aux normes mentionnées. • Les distances d’installation peuvent varier selon le code local. L’installateur doit vérifier les exigences d’installation.
www.camplux.com • Si les instructions indiqués sur l'étiquette d'instruction / d'avertissement située sur le panneau avant du chauffe-eau diffèrent, installez le chauffe-eau conformément aux instructions indiqués sur le manuel. AVERTISSEMENT: La construction combustible fait référence aux murs et aux plafonds adjacents et ne doit pas être confondue avec des produits et matériaux combustibles ou inflammables.
www.camplux.com 11 Vérifier L'Unité Inspectez le chauffe-eau pour des dommages possibles. Vérifiez les instructions sur la plaque signalétique du chauffe-eau pour vous assurer que le type de gaz fourni correspond aux exigences du chauffe-eau. Vérifiez que toutes les pièces incluses sont présentes (voir ci-dessous).
www.camplux.com CONNEXIONS D'ALIMENTATION EN EAU La plomberie doit être effectuée par un plombier qualifié conformément aux codes locaux. N'utilisez que du matériel et des outils d'approbation de plomberie. Installez un clapet anti-retour entre le chauffe-eau et le robinet d'arrêt d'eau. (Voir illustration ci-dessous). Pour économiser de l'énergie et éviter le gel, isolez les conduites d'alimentation en eau froide et en eau chaude. NE PAS couvrir les vannes de vidange.
www.camplux.com 13 IMPORTANT: N'appliquez pas de chaleur sur les raccords d'eau chaude ou froide. Toute chaleur appliquée aux raccords d'alimentation en eau endommagera de manière permanente les composants internes du chauffe-eau. AVIS: Si la résistance du pomme de douche au débit d'eau est trop élevée, le brûleur dans le chauffe-eau ne s'allumera pas. Gardez la pomme de douche propre de tout débris qui pourrait causer une chute de pression supplémentaire.
www.camplux.com APPROVISIONNEMENT EN GAZ AVERTISSEMENT: N'essayez pas d’utiliser ce chauffe-eau avec un type de gaz différent de celui indiqué sur la plaque signalétique. Un tel changement pourrait entraîner des conséquences de fonctionnement dangereuses. Veuillez demander à un professionnel de connecter le tuyau de gaz. Le robinet d'arrêt manuel de l'appareil au gaz fourni doit être installée sur le raccord de gaz du chauffe-eau au moment de l'installation.
www.camplux.com 15 SOUPAPE DE RELIEF Une nouvelle soupape de surpression, conforme à la norme ANSI Z21.22, relative aux soupapes de décharge et aux dispositifs d'arrêt automatique du gaz pour les systèmes d'alimentation en eau chaude, doit être installée sur le raccord de sortie d'eau chaude du chauffe-eau au moment de l'installation. Les codes locaux doivent régir l’installation des soupapes de décharge.
www.camplux.com 16 Test De Fuite AVERTISSEMENT: N'utilisez jamais une flamme nue pour rechercher des fuites de gaz, vous risqueriez des dommages matériels, des blessures ou la mort. Le chauffe-eau et ses raccords de gaz doivent faire l'objet d'un test d'étanchéité à des pressions de fonctionnement normales avant d'être mis en service. • Ouvrir le (s) robinet (s) d’arrêt de gaz du chauffe-eau.
www.camplux.com 17 Utilisez un tuyau de ventilation avec une structure anti-raccordement. L'utilisation d’une silicone haute température (500°F) peut être nécessaire pour sceller les raccords de ventilation. Pour éviter les fuites accidentelles de gaz, appliquez un cordon large de 1/4 ”à environ 1/4” de l'extrémité et un autre cordon contre le côté joint du cordon d'arrêt. Suivez les instructions d’installation du fabricant. L'unité peut être ventilée horizontalement ou verticalement.
www.camplux.com LONGUEURS DE VENTILATION Longueur Maximale De L'Évent Le propriétaire doit se référer aux instructions et spécifications du fabricant de l’évent. Le système ne fonctionnera pas s'il y a une restriction excessive (chute de pression) dans le système de ventilation. Un tuyau de ventilation de maximum 32 pieds peut être utilisé à condition qu'il n'y ait qu'un seul coude à 90° dans le système.
www.camplux.
www.camplux.com Pour les dégagements non spécifiés dans les normes ANSI Z223.1 / NFPA 54 ou CSA-B149.1, l'un des éléments suivants doit être indiqué: A) Une valeur de jeu minimale déterminée par des essais conformément à la Clause 5.20 ou; B) Une des références suivantes : Espace libre conformément aux codes d'installation locaux et aux exigences du fournisseur de gaz.
www.camplux.com 21 Section Intérieure Du Dé À Coudre Section Extérieure Du Dé À Coudre Vue De Côté ATTENTION: Utilisez uniquement un matériau de ventilation de catégorie III approuvé par UL. Tout autre matériau de ventilation est autorisé. Le propriétaire doit se référer aux instructions et spécifications du fabricant de l’évent. Veuillez vous rendre dans une quincaillerie locale ou sur des marchés en ligne pour acheter un évent en acier inoxydable de catégorie III pour une installation certifiée.
www.camplux.com (FACULTATIF) TÉLÉCOMMANDE CONNEXION, INSTALLATION ET SET 22 (Pour Panneau De Contrôle / Télécommande Et Unités De Contrôle À Distance) Les unités Panneau de contrôle / Télécommande et Télécommande fonctionneront avec une ou deux télécommandes. Si deux télécommandes sont souhaitées, un connecteur de fil devra être fourni. Pour connecter la télécommande. 1.
www.camplux.com 23 Base De Contrôle Mur Vis En Caoutchouc Vis À Bois 3. Replacez le capot avant de la télécommande. AVERTISSEMENT: Les connexions de câblage sur le terrain et la mise à la terre électrique doivent être conformes aux codes locaux, ou en l’absence de codes locaux, à la dernière édition du Code national de l’électricité, ANSI / NFPA 70, ou au Canada, Code canadien de l’électricité, CSA C22. .1Part1.
www.camplux.com HARDWIRING ELECTRICAL 24 LES LIAISONS • Le câblage doit être effectué par un électricien qualifié conformément aux codes locaux. • Le chauffe-eau nécessite 120 VCA / 60 Hz et doit être correctement mis à la terre. • NE PAS brancher le fil de terre sur les conduites d'eau, les conduites de gaz, les câbles téléphoniques, les circuits de parafoudre et sur le circuit de mise à la terre d'autres équipements dotés d'un disjoncteur de fuite à la terre.
www.camplux.com 25 COUVERTURE D'ISOLATION AVERTISSEMENT: si les codes locaux exigent l’application externe de kits de couverture isolante, il convient de suivre scrupuleusement les instructions du fabricant fournies avec le kit. Les couvertures isolantes, disponibles pour le grand public, à usage externe sur les chauffe-eau à gaz ne sont pas nécessaires. Les matelas isolants ont pour but de réduire les pertes de chaleur en mode veille générées par les éléments chauffants des réservoirs de stockage.
www.camplux.com 26 Entrée De Gaz Eau Chaude Clapet Anti-retour Tuyau D'entrée Eau Froide AVIS: Les tuyaux chauds et froids doivent être isolés comme indiqué afin de fournir une protection supplémentaire contre le gel. PENDANT L’INSTALLATION DE CE CHAUFFE EAU VEUILLEZ A BIEN : • Vérifiez la pression de gaz à l'entrée pour vous assurer qu'elle se situe dans la plage indiquée sur la plaque signalétique.
www.camplux.com 27 MONTAGE DU CHAUFFE-EAU Assurez-vous que l'emplacement du chauffe-eau permet un accès et un fonctionnement facile. En cas de mur sec ou de mur en béton, utilisez des ancrages pour mur sec ou des tire-fonds. Le chauffe-eau nécessite 120V AC / 60Hz. Ayez une prise avec une borne de terre près du chauffe-eau. La longueur du cordon d'alimentation est de 5 pieds.
www.camplux.com 28 Liste De Contrôle D'installation A. Emplacement du chauffe-eau • Installé à l'intérieur. • Près de la zone de sortie la plus utilisée. • Protégé du gel. • Le dégagement adéquat des surfaces combustibles est observé. • Alimentation en air frai suffisant pour le bon fonctionnement du chauffe-eau. • Air fourni sans éléments corrosifs ni vapeurs inflammables. • Dispositions prises pour protéger la zone des dégâts d’eau. • Suffisamment de place pour entretenir le chauffage.
www.camplux.com 29 POUR VOTRE SÉCURITÉ AVANT D'UTILISER LE CHAUFFE-EAU AVERTISSEMENT: Suivez bien les instructions données dans le présent manuel pour réduire au minimum le risque d’incendie ou d’explosion et prévenir les blessures, la mort ou les dommages matériels A. B. Cet appareil ne comporte pas de veilleuse d’allumage. Il est muni d’un dispositif d’allumage qui allume automatiquement le brûleur. NE PAS tenter d’allumer le brûleur à la main.
www.camplux.com UTILISATION DU CHAUFFE-EAU Allumer Le Chauffe-eau 1. Assurez-vous que le type de gaz que vous utiliserez est identique à celui indiqué sur la plaque signalétique. 2. Ouvrez le robinet de gaz principal, branchez le cordon d'alimentation (assurez-vous que la prise est bien mise à la terre) et appuyez sur le bouton “ON/OFF” du panneau de commande. Réglez la température à 120°F. 3. Ouvrez le robinet et le ventilateur commencera à fonctionner.
www.camplux.com 31 La température de sortie de l'eau est réglée en réglant la température à l'avant de la télécommande. Les facteurs de sécurité doivent être pris en compte lors du choix du réglage de la température de l’eau de la télécommande du chauffe-eau. La télécommande était réglée à 110°F avant que le chauffe-eau ne soit expédié de l'usine. C'est le point de départ recommandé. Des températures de l'eau supérieures à 120°F peuvent provoquer des brûlures graves, voire mortelles, dues à des brûlures.
www.camplux.com La Qualité D'Eau Pour une qualité d'eau chaude répond aux normes de qualité EPA, il est nécessaire de suivre les instructions d'entretien mentionner sur ce manuel • Le tableau suivant indique les concentrations maximales de contaminants autorisées, conformément au règlement national sur l'eau potable secondaire de l'EPA (40 CFR, partie 143.3).
www.camplux.com 33 Inspecter l'environnement du chauffe-eau pour garantir fonctionnement efficace. Gardez la zone du chauffe-eau dégagée et exempte de matériaux combustibles, d'essence et d'autres liquides et vapeurs inflammables. Assurez-vous que l'unité n'a pas été endommagée. En cas de dommage ou de bossèlement, contactez un technicien de maintenance pour vérifier son bon fonctionnement. Vérifiez qu'il n'y a aucun bruit anormal pendant le fonctionnement normal du chauffe-eau.
www.camplux.com Passez régulièrement l'aspirateur autour du chauffe-eau pour éliminer la poussière, la saleté et les peluches. Nettoyez le chauffe-eau et la télécommande en utilisant un chiffon doux et humide avec quelques gouttes de détergent doux et en essuyant délicatement les surfaces de l'appareil. Essuyez toute trace d'humidité avec un chiffon doux et sec. Pour assurer une ventilation et une alimentation en air de combustion suffisantes, des dégagements appropriés doivent être respectés.
www.camplux.com PROCÉDURE DE DRAINAGE 35 Lorsque la température tombe en dessous de 32°F, l'eau de votre système de plomberie ou de votre chauffe-eau peut se transformer en glace, puis se dilater et causer des dommages au chauffe-eau. Ces dommages ne sont pas couverts par la garantie du fabricant. Si ces conditions sont prévues, veuillez vider le chauffe-eau comme suit pour éviter le gel: 1. Fermer la vanne de gaz principale et le mettre sous tension. 2. Fermer le robinet d'arrivée d'eau. 3.
www.camplux.com 8. Remontez le filtre à eau. Fermer le robinet de vidange de sortie d'eau chaude. 9. Ouvrez le robinet d’arrêt d’eau et fermez-le de nouveau après s’être assuré que l’eau sortait des robinets d’eau chaude. (Cette étape consiste à éliminer l'air des lignes d'eau.) 10. Rebranchez le disjoncteur et mettez l'interrupteur on / off en position ON, ouvrez complètement le robinet d'arrêt de gaz et le robinet d'arrêt d'eau.
www.camplux.com 37 GUIDE DE CODE D'ERREUR Lorsqu'un code d'erreur est affiché: • Fermer le robinet d'eau chaude, éteindre l'interrupteur de la télécommande. • Attendez environ 5 minutes avant de rallumer l’interrupteur. • Ouvrez le robinet d'eau chaude. AVIS: Si un code d'erreur autre que ceux énumérés ci-dessous s'affiche, fermez immédiatement le robinet d'eau chaude, notez-le, éteignez le commutateur de la télécommande et appelez le numéro d'assistance clientèle.
www.camplux.com PIÈCES DE RECHANGE 38 Pour les modèles utilisant du gaz naturel ou du gaz propane. AVERTISSEMENT: Pour votre sécurité, NE tentez PAS de démonter cet appareil pour quelque raison que ce soit. 20.Sortie D'échappement 19.Collecteur D'échappement 18.Thermostat Anti-gel 1.Échangeur De Chaleur 17.Thermostat 16.Anti-congélateur 2.Aiguille D'allumage 15.Dispositif De Protection De L'échangeur De Chaleur 2.Aiguille D'allumage 14.Ensemble Du Brûleur 3.Aiguille Du Capteur De Flamme 13.
www.camplux.com 39 EN BOÎTE Article Description De L'article A Résidentiel Sans Réservoir Chauffe-eau Au Gaz B Tuyau De Ventilation (Φ3.0”) C Soupape De Sûreté Identification Quantité 1 pièce NOT INCLUDED N/A N/A D Kits De Fixation 1 jeu E Manuel 1 pièce NOTE: Vent Pipe was not included from the original package. Please visit a local hardware store or online marketplaces to purchase Φ3” Category III Stainless Steel Venting for certified installation.
www.camplux.com CAMPLUX, PROFITEZ DE LA VIE EXTÉRIEURE! INFORMATION DE GARANTIE LIMITÉE Camplux garantit par la présente que ce produit est exempt de tout défaut matériel et de fabrication lorsqu’il est installé et utilisé conformément aux instructions d’installation et d’utilisation de Camplux. Cette garantie limitée s’applique à l’acheteur initial et aux propriétaires ultérieurs, mais uniquement tant que le produit reste sur le site de l’installation initiale.
www.camplux.com 41 NOS AUTRES MODÈLES RÉSIDENTIELS WA686 CA318 CM264 CM264 CA318 WA686 Utiliser Pour À L'INTÉRIEUR SEULEMENT À L'INTÉRIEUR SEULEMENT EXTÉRIEUR UNIQUEMENT BTU 68,000 82,000 180,000 Débit Classé 2.64 GPM Classé 3.18 GPM Classé 6.86 GPM Portable Non Non Non Source D'énergie 120 volts 120 volts 120 volts Type De Gaz Propane Liquide Et Gaz Naturel Propane Liquide Et Gaz Naturel Propane Liquide Et Gaz Naturel Pression De L'eau 3.6-150 PSI 3.6-150 PSI 3.
3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com (844) 538-7475 support@camplux.